Skip to product information
1 of 10

Eaton 9SX 3000VA 2700W 208V Online Double-Conversion UPS - 2 NEMA 6-20R 1 L6-30R 2 L6-20R Outlets Cybersecure Network Card Option Extended Run Tower

Eaton 9SX 3000VA 2700W 208V Online Double-Conversion UPS - 2 NEMA 6-20R 1 L6-30R 2 L6-20R Outlets Cybersecure Network Card Option Extended Run Tower

SKU: 1053041161      MFR: Eaton Corporation

GTIN: 743172091321

Product Description

Eaton 9SX 3000VA 2700W 208V Online Double-Conversion UPS - 2 NEMA 6-20R 1 L6-30R 2 L6-20R Outlets Cybersecure Network Card Option Extended Run Tower - Tower - 5.80 Minute Stand-by - 230 V AC Input - 200 V AC 208 V AC 220 V AC 230 V AC 240 V AC Output - 1 x NEMA L6-30R 2 x NEMA L6-20R 2 x NEMA 6-20R

Manufacturer : Eaton Corporation

Manufacturer Part No : 9SX3000GL

Features

  • Zero transfer time between on-line and battery modes for uninterrupted operation
  • NEMA L6-20P input with one L6-30R 2 L6-20R and 2 6-20R outlets for devices
  • Optional NETWORK-M2 network card enables full remote access and control
  • Front-panel LCD keeps you up to date with status info and other vital analytics
  • Optional external battery modules allow extended runtime to keep equipment running

Product Details

Product TypeDouble Conversion Online UPS
Receptacle TypeNEMA L6-30R
Backup/Run Time (Full Load)5.80 Minute
Load Capacity (VA)3000 VA
Load Capacity (W)2700 W
Brand NameEaton
Plug/Connector TypeNEMA L6-20P
Input Voltage Range190 V AC - 276 V AC
Form FactorTower
Waveform TypeSine Wave
Application/UsageIndustrial Equipment
Input Voltage230 V AC
Receptacle Detail1 x NEMA L6-30R
Country of OriginPhilippines
Load Capacity3000 VA/2700 W
ManufacturerEaton Corporation
Product Name3000VA Tower UPS
Manufacturer Part Number9SX3000GL
Manufacturer Website Addresshttp://www.eaton.com
Marketing InformationDouble-Conversion UPS Protects Equipment Against Damage Downtime and Data Loss This 9SX on-line double-conversion UPS system maintains perfect output by converting AC input to DC then reconverting UPS output to fully regulated sine wave AC. Featuring surge suppression true on-line operation with pure sine wave output and zero transfer time between on-line and battery modes the 9SX3000GL provides the highest level of AC power protection and battery backup for medical light industrial automation and other mission-critical IT applications where space is limited but premium power reliability is essential. Reliable Expandable Battery Backup Keeps You Operational Through Power Outages The field-replaceable hot-swappable internal battery modules allow you to work through short power failures and give you enough time to safely save files and shut down your system in case of a prolonged blackout. Exclusive ABM technology increases battery life by 50 percent and closely monitors battery health to provide advanced notice when batteries need replacing. You can also connect up to four external battery modules (9SXEBM96 sold separately) for hours of extended runtime. Optional Gigabit Network Interface Offers 24/7 Remote Access The NETWORK-M2 network card (sold separately) enables full remote configuration and management including load shedding reboots of connected equipment and safe shutdowns. UPS firmware can also be flashed remotely through the NETWORK-M2 without dropping the load so you don't have to plan for downtime. The card meets both UL 2900-1 and IEC 62443-4-2 standards for cybersecurity which were developed to address the vulnerability of connected devices to known malware/exploits and to protect business from these risks. An optional Environmental Monitoring Probe Gen 2 (EMPDT1H1C2 sold separately) provides a variety of environmental monitoring capabilities including temperature and humidity conditions. NEMA Outlets Protect Your Connected Components One L6-30R two L6-20R and two 6-20R outlets provide connected equipment with pure sine wave AC output and allow you to monitor power consumption down to the outlet group level. Power provided by these outlets is filtered to protect connected equipment against damaging surges and line noise. Two load banks each contain one L6-20R outlet and one 6-20R outlet. The banks allow you to shed non-critical loads to extend runtime for critical loads.
Package Contents
  • 3000VA Tower UPS
  • Manual
  • Quick Start Guide
  • Safety Guide
  • Serial And USB Cables
Limited Warranty2 Year
Output Voltage200 V AC
Weight (Approximate)77.20 lb
Receptacle Detail2 x NEMA 6-20R
Receptacle TypeNEMA 6-20R
View full details
Regular price $4,698.99 USD
Regular price Sale price $4,698.99
Sale Sold out

Out Of Stock


Update

   

Shipping calculated at checkout.

Eaton 9SX 3000VA 2700W 208V Online Double-Conversion UPS - 2 NEMA 6-20R 1 L6-30R 2 L6-20R Outlets Cybersecure Network Card Option Extended Run Tower - Tower - 5.80 Minute Stand-by - 230 V AC Input - 200 V AC 208 V AC 220 V AC 230 V AC 240 V AC Output - 1 x NEMA L6-30R 2 x NEMA L6-20R 2 x NEMA 6-20R

Manufacturer : Eaton Corporation

Manufacturer Part No : 9SX3000GL

Features

  • Zero transfer time between on-line and battery modes for uninterrupted operation
  • NEMA L6-20P input with one L6-30R 2 L6-20R and 2 6-20R outlets for devices
  • Optional NETWORK-M2 network card enables full remote access and control
  • Front-panel LCD keeps you up to date with status info and other vital analytics
  • Optional external battery modules allow extended runtime to keep equipment running

Product Details

Product TypeDouble Conversion Online UPS
Receptacle TypeNEMA L6-30R
Backup/Run Time (Full Load)5.80 Minute
Load Capacity (VA)3000 VA
Load Capacity (W)2700 W
Brand NameEaton
Plug/Connector TypeNEMA L6-20P
Input Voltage Range190 V AC - 276 V AC
Form FactorTower
Waveform TypeSine Wave
Application/UsageIndustrial Equipment
Input Voltage230 V AC
Receptacle Detail1 x NEMA L6-30R
Country of OriginPhilippines
Load Capacity3000 VA/2700 W
ManufacturerEaton Corporation
Product Name3000VA Tower UPS
Manufacturer Part Number9SX3000GL
Manufacturer Website Addresshttp://www.eaton.com
Marketing InformationDouble-Conversion UPS Protects Equipment Against Damage Downtime and Data Loss This 9SX on-line double-conversion UPS system maintains perfect output by converting AC input to DC then reconverting UPS output to fully regulated sine wave AC. Featuring surge suppression true on-line operation with pure sine wave output and zero transfer time between on-line and battery modes the 9SX3000GL provides the highest level of AC power protection and battery backup for medical light industrial automation and other mission-critical IT applications where space is limited but premium power reliability is essential. Reliable Expandable Battery Backup Keeps You Operational Through Power Outages The field-replaceable hot-swappable internal battery modules allow you to work through short power failures and give you enough time to safely save files and shut down your system in case of a prolonged blackout. Exclusive ABM technology increases battery life by 50 percent and closely monitors battery health to provide advanced notice when batteries need replacing. You can also connect up to four external battery modules (9SXEBM96 sold separately) for hours of extended runtime. Optional Gigabit Network Interface Offers 24/7 Remote Access The NETWORK-M2 network card (sold separately) enables full remote configuration and management including load shedding reboots of connected equipment and safe shutdowns. UPS firmware can also be flashed remotely through the NETWORK-M2 without dropping the load so you don't have to plan for downtime. The card meets both UL 2900-1 and IEC 62443-4-2 standards for cybersecurity which were developed to address the vulnerability of connected devices to known malware/exploits and to protect business from these risks. An optional Environmental Monitoring Probe Gen 2 (EMPDT1H1C2 sold separately) provides a variety of environmental monitoring capabilities including temperature and humidity conditions. NEMA Outlets Protect Your Connected Components One L6-30R two L6-20R and two 6-20R outlets provide connected equipment with pure sine wave AC output and allow you to monitor power consumption down to the outlet group level. Power provided by these outlets is filtered to protect connected equipment against damaging surges and line noise. Two load banks each contain one L6-20R outlet and one 6-20R outlet. The banks allow you to shed non-critical loads to extend runtime for critical loads.
Package Contents
  • 3000VA Tower UPS
  • Manual
  • Quick Start Guide
  • Safety Guide
  • Serial And USB Cables
Limited Warranty2 Year
Output Voltage200 V AC
Weight (Approximate)77.20 lb
Receptacle Detail2 x NEMA 6-20R
Receptacle TypeNEMA 6-20R

Recently Viewed