Server Technology PRO1 C1W08HC-1DCA2BA5 8-Outlets PDU
Server Technology PRO1 C1W08HC-1DCA2BA5 8-Outlets PDU
SKU: 1067788307 MFR: Server Technology Inc
Product Description
Server Technology PRO1 C1W08HC-1DCA2BA5 8-Outlets PDU - Switched - NEMA L5-30P - 8 x NEMA 5-20R - 120 V AC - Network (RJ-45) - 1U - Rack-mountable Cabinet-mountable - Hot-swappable
Manufacturer : Server Technology Inc
Manufacturer Part No : C1X08HC-1DCA2BA5
Features
- Network Monitoring
- Gain access to valuable data through connections including HTTP(S) SSH Telnet SNMP (S)FTP SMTP Syslog LDAP(S) RS-23 2 serial and more.
- Hot - Swap Network Card
- Network access is ensured when power is lost to the Primary unit with backup power provided by the Linked unit.
- Star Multi - Linking
- PRO2 provides the ability to link up to four power circuits using one IP address. Primary Expansion PDU provides backup power to network card.
- Temperature/Humidity Monitoring
- Primary and Expansion (select pro ducts) units each support two external 10' (3 m) T/H probes. Receive SNMP-based alerts and email notifications.
- IP Access Security & Communications
- Web SSH Telnet SNMPv2c & v3 RS-23 2 serial 10/100 Base T-Ethernet LDAP(S) TACACS+ RADIUS DHCP & SMTP/email.
- Auto-Flip Current Display
- Easy-to -read LEDs display current per phase to help prevent overloads and simplify three-phase load balancing in high-density cabinets.
- Per - Inlet Power Sensing
- PIPS® (Per Inlet Power Sensing) Monitors Current Load (A) Voltage (V) Power (W) Apparent Power (VA) Crest Factor Power Factor & Energy per inlet
- .
- Branch Circuit Protection
- This PDU meets the UL and IEC 62368 -1 requirement for branch circuit protection through UL 48 9 rated magnetic-hydraulic circuit breakers or UL 248 fuses.
- Outlet Control
- On Switched PDUs cycle power to individual outlets or groups of outlets to reboot servers or power off unused receptacles.
- High Retention Locking Outlets
- PRO2 receptacles have high retention and are compatible with P-Lock type power cords.
- High Temperature Rating
- This product has been tested and approved for safe and reliable operation in 60 °C data center environments.
- Color - Coded Options
- Select from six colors to designate PDU circuits in the data center - black white red green blue and yellow.
Product Details
- HTTP/HTTPS
- TLSv1.2
- SSHv2
- Telnet
- SNMPv2c
- v3 (GET SET Traps)
- IPv4
- IPv6
- LDAPv3/LDAPS
- TACACS+
- RADIUS
- FTP/SFTP
The Server Technology® PRO1 Switched PDU provides control of outlet power and local LED input current monitoring allowing IT personnel to determine safe levels of loading on a per-phase basis while installing equipment into the rack/cabinet. The integral PIPS® technology provides billing grade accurate measurement of current voltage active power apparent power power factor crest factor and accumulated energy at the input. These power data points along with temperature and humidity measurements (provided via optional probes) are accessible through the built-in Web and CLI interfaces as well as through SNMP. The PRO1 Switched "Primary" PDU can be connected to as many as three (with optional module)PRO1 Switched "Link" PDUs to extend the network access to the redundant or secondary power feed without the risks of a daisy chain linking configuration.
- PRO1 C1W08HC-1DCA2BA5 8-Outlets PDU
- Mounting Brackets
Out Of Stock
Update
Server Technology PRO1 C1W08HC-1DCA2BA5 8-Outlets PDU - Switched - NEMA L5-30P - 8 x NEMA 5-20R - 120 V AC - Network (RJ-45) - 1U - Rack-mountable Cabinet-mountable - Hot-swappable
Manufacturer : Server Technology Inc
Manufacturer Part No : C1X08HC-1DCA2BA5
Features
- Network Monitoring
- Gain access to valuable data through connections including HTTP(S) SSH Telnet SNMP (S)FTP SMTP Syslog LDAP(S) RS-23 2 serial and more.
- Hot - Swap Network Card
- Network access is ensured when power is lost to the Primary unit with backup power provided by the Linked unit.
- Star Multi - Linking
- PRO2 provides the ability to link up to four power circuits using one IP address. Primary Expansion PDU provides backup power to network card.
- Temperature/Humidity Monitoring
- Primary and Expansion (select pro ducts) units each support two external 10' (3 m) T/H probes. Receive SNMP-based alerts and email notifications.
- IP Access Security & Communications
- Web SSH Telnet SNMPv2c & v3 RS-23 2 serial 10/100 Base T-Ethernet LDAP(S) TACACS+ RADIUS DHCP & SMTP/email.
- Auto-Flip Current Display
- Easy-to -read LEDs display current per phase to help prevent overloads and simplify three-phase load balancing in high-density cabinets.
- Per - Inlet Power Sensing
- PIPS® (Per Inlet Power Sensing) Monitors Current Load (A) Voltage (V) Power (W) Apparent Power (VA) Crest Factor Power Factor & Energy per inlet
- .
- Branch Circuit Protection
- This PDU meets the UL and IEC 62368 -1 requirement for branch circuit protection through UL 48 9 rated magnetic-hydraulic circuit breakers or UL 248 fuses.
- Outlet Control
- On Switched PDUs cycle power to individual outlets or groups of outlets to reboot servers or power off unused receptacles.
- High Retention Locking Outlets
- PRO2 receptacles have high retention and are compatible with P-Lock type power cords.
- High Temperature Rating
- This product has been tested and approved for safe and reliable operation in 60 °C data center environments.
- Color - Coded Options
- Select from six colors to designate PDU circuits in the data center - black white red green blue and yellow.
Product Details
- HTTP/HTTPS
- TLSv1.2
- SSHv2
- Telnet
- SNMPv2c
- v3 (GET SET Traps)
- IPv4
- IPv6
- LDAPv3/LDAPS
- TACACS+
- RADIUS
- FTP/SFTP
The Server Technology® PRO1 Switched PDU provides control of outlet power and local LED input current monitoring allowing IT personnel to determine safe levels of loading on a per-phase basis while installing equipment into the rack/cabinet. The integral PIPS® technology provides billing grade accurate measurement of current voltage active power apparent power power factor crest factor and accumulated energy at the input. These power data points along with temperature and humidity measurements (provided via optional probes) are accessible through the built-in Web and CLI interfaces as well as through SNMP. The PRO1 Switched "Primary" PDU can be connected to as many as three (with optional module)PRO1 Switched "Link" PDUs to extend the network access to the redundant or secondary power feed without the risks of a daisy chain linking configuration.
- PRO1 C1W08HC-1DCA2BA5 8-Outlets PDU
- Mounting Brackets
Recently Viewed
We’re a veteran-owned small business with full-stack expertise. We’ll help you design, coordinate, and manage technology solutions that will drive your business forward.
- About Us
- Contact Us
- My Account
- Prospective Investors
Quick Links
Contracts
Contact Us
-
6402 Corporate Dr, Suite 103,
Indianapolis, IN 46278 - (317) 243-1750
- sales@tekmentum.com
- Mon-Fri: 8:00am-5:00pm
© 2005-2023, Tekmentum. All Rights Reserved. A KPaul, LLC Company.
- Choosing a selection results in a full page refresh.
- Opens in a new window.