Server Technology PRO3X C3W36RL-DCJE2MT3 36-Outlets PDU
Server Technology PRO3X C3W36RL-DCJE2MT3 36-Outlets PDU
SKU: 1068138020 MFR: Server Technology Inc
Product Description
Server Technology PRO3X C3W36RL-DCJE2MT3 36-Outlets PDU - Switched - NEMA L15-30P - 18 x IEC 60320 C13 18 x CX - 230 V AC - Network (RJ-45) - 0U - Button Mount - Hot-swappable
Manufacturer : Server Technology Inc
Manufacturer Part No : C3W36RL-DCJE2MT3
Features
- HDOT CX OUTLETS
- Cx is the future-ready UL tested hybrid of a C13 and C19 outlet accommodating both C14 and C20 plugs.
- NETWORK MONITORING
- Gain access to valuable data through connections including HTTP(S) SSH Telnet SNMP (S)FTP SMTP Syslog LDAP(S) RS-232 serial and more.
- MULTI-UNIT LINKING & CASCADING
- Daisy chain up to 16 PDUs from a primary PDU using a USB or Ethernet connection through a single IP address.
- MULTI-COLOR LCD
- An easy-to-read LCD provides a local indication of power usage alerts and alarms.
- HOT SWAPPABLE CONTROLLER
- The Controller is the PDU's center of intelligence and houses computing display and connectivity ports.
- RAMLOCK LOCKING OUTLETS
- A mechanical locking mechanism built to secure the broadest range of C14 and C20 plugs in place.
- ENVIRONMENTAL MONITORING
- Support up to 12 daisy chained DX2-series SmartSensors each with the ability to send SNMP-based alerts and email notifications.
- PER-INLET POWER SENSING
- PIPS® (Per Inlet Power Sensing) Monitors Current Load (A) Voltage (V) Power (W) Apparent Power (VA) Crest Factor Power Factor & Energy per inlet.
- BRANCH CURRENT MONITORING
- Monitors current at each breaker branch and provides SNMP-based alerts and emails on high usage that risks a tripped circuit.
- BRANCH CIRCUIT PROTECTION
- This PDU meets the UL and IEC 62368-1 requirement for branch circuit protection through UL 489 rated magnetic-hydraulic circuit breakers or UL 248 fuses.
- OUTLET CONTROL
- On Switched PDUs cycle power to individual outlets or groups of outlets to reboot servers or power off unused receptacles.
- HIGH TEMPERATURE RATING
- This product has been tested and approved for safe and reliable operation in 60 °C data center environments.
- FLEXIBLE MOUNTING
- Includes standard button mounts along with provisions for custom mounting brackets.
- Color - Coded Options
- Select from six colors to designate PDU circuits in the data center - black white red green blue and yellow.
Product Details
- PRO3X C3W36RL-DCJE2MT3 36-Outlets PDU
- Button Mounts
- HTTP/HTTPS
- TLSv1.2
- SSHv2
- Telnet
- SNMPv2c
- v3 (GET SET Traps)
- IPv4
- IPv6
- LDAPv3/LDAPS
- TACACS+
- RADIUS
- FTP/SFTP
This all new Server Technology PRO3X Switched PDU features RamLock HDOT outlets running with the Xerus Technology Platform's state of the art network interface module. Server Technology's unique RamLock a self-locking elbow-catch mechanism to prevent accidental cord disconnects on standard network power cords. The PDU features HDOT outlets which are dedicated C13 outlets while the other HDOT Cx outlets can be treated as either a C13 or C19 outlet. This innovative PDU combines input power and branch current monitoring and outlet control and supports Legrand plug-and-play sensor types like temperature humidity water dry contact closure airflow air pressure differential and more.
Back Order
Get it by Thu, Feb 05 - Tue, Feb 10
Update
Couldn't load pickup availability
Server Technology PRO3X C3W36RL-DCJE2MT3 36-Outlets PDU - Switched - NEMA L15-30P - 18 x IEC 60320 C13 18 x CX - 230 V AC - Network (RJ-45) - 0U - Button Mount - Hot-swappable
Manufacturer : Server Technology Inc
Manufacturer Part No : C3W36RL-DCJE2MT3
Features
- HDOT CX OUTLETS
- Cx is the future-ready UL tested hybrid of a C13 and C19 outlet accommodating both C14 and C20 plugs.
- NETWORK MONITORING
- Gain access to valuable data through connections including HTTP(S) SSH Telnet SNMP (S)FTP SMTP Syslog LDAP(S) RS-232 serial and more.
- MULTI-UNIT LINKING & CASCADING
- Daisy chain up to 16 PDUs from a primary PDU using a USB or Ethernet connection through a single IP address.
- MULTI-COLOR LCD
- An easy-to-read LCD provides a local indication of power usage alerts and alarms.
- HOT SWAPPABLE CONTROLLER
- The Controller is the PDU's center of intelligence and houses computing display and connectivity ports.
- RAMLOCK LOCKING OUTLETS
- A mechanical locking mechanism built to secure the broadest range of C14 and C20 plugs in place.
- ENVIRONMENTAL MONITORING
- Support up to 12 daisy chained DX2-series SmartSensors each with the ability to send SNMP-based alerts and email notifications.
- PER-INLET POWER SENSING
- PIPS® (Per Inlet Power Sensing) Monitors Current Load (A) Voltage (V) Power (W) Apparent Power (VA) Crest Factor Power Factor & Energy per inlet.
- BRANCH CURRENT MONITORING
- Monitors current at each breaker branch and provides SNMP-based alerts and emails on high usage that risks a tripped circuit.
- BRANCH CIRCUIT PROTECTION
- This PDU meets the UL and IEC 62368-1 requirement for branch circuit protection through UL 489 rated magnetic-hydraulic circuit breakers or UL 248 fuses.
- OUTLET CONTROL
- On Switched PDUs cycle power to individual outlets or groups of outlets to reboot servers or power off unused receptacles.
- HIGH TEMPERATURE RATING
- This product has been tested and approved for safe and reliable operation in 60 °C data center environments.
- FLEXIBLE MOUNTING
- Includes standard button mounts along with provisions for custom mounting brackets.
- Color - Coded Options
- Select from six colors to designate PDU circuits in the data center - black white red green blue and yellow.
Product Details
- PRO3X C3W36RL-DCJE2MT3 36-Outlets PDU
- Button Mounts
- HTTP/HTTPS
- TLSv1.2
- SSHv2
- Telnet
- SNMPv2c
- v3 (GET SET Traps)
- IPv4
- IPv6
- LDAPv3/LDAPS
- TACACS+
- RADIUS
- FTP/SFTP
This all new Server Technology PRO3X Switched PDU features RamLock HDOT outlets running with the Xerus Technology Platform's state of the art network interface module. Server Technology's unique RamLock a self-locking elbow-catch mechanism to prevent accidental cord disconnects on standard network power cords. The PDU features HDOT outlets which are dedicated C13 outlets while the other HDOT Cx outlets can be treated as either a C13 or C19 outlet. This innovative PDU combines input power and branch current monitoring and outlet control and supports Legrand plug-and-play sensor types like temperature humidity water dry contact closure airflow air pressure differential and more.
Recently Viewed
We’re a veteran-owned small business with full-stack expertise. We’ll help you design, coordinate, and manage technology solutions that will drive your business forward.
- About Us
- Contact Us
- My Account
- Prospective Investors
Quick Links
Contracts
Contact Us
-
6402 Corporate Dr, Suite 103,
Indianapolis, IN 46278 - (317) 243-1750
- sales@tekmentum.com
- Mon-Fri: 8:00am-5:00pm
© 2005-2023, Tekmentum. All Rights Reserved. A KPaul, LLC Company.
- Choosing a selection results in a full page refresh.
- Opens in a new window.