Tripp Lite Isolator Series 120V 1800W UL 60601-1 Medical-Grade Isolation Transformer with 6 Hospital-Grade Outlets
Tripp Lite Isolator Series 120V 1800W UL 60601-1 Medical-Grade Isolation Transformer with 6 Hospital-Grade Outlets
SKU: 11746933 MFR: Tripp Lite by Eaton
GTIN: 37332116222
Product Description
Tripp Lite Isolator Series 120V 1800W UL 60601-1 Medical-Grade Isolation Transformer with 6 Hospital-Grade Outlets - 1800W - 120V AC
Manufacturer : Tripp Lite by Eaton
Manufacturer Part No : IS1800HG
Features
- Complete line isolation noise filtering and surge suppression; ideal for sensitive equipment
- 1800 watts 6 outlets 10-ft. power cord
- Hospital-grade plug and receptacles
- Leakage current less than 100 microamps
- Compliant with the Federal Trade Agreements Act (TAA) for GSA Schedule purchases
Product Details
- Hospital Grade Outlets and Plug
- 20A circuit breaker
- Total Harmonic Distortion: Less than 1%
- Rugged all-metal unit housing
- Cooling Method: Convection
- Noise Suppression Rating: 35-65 DB
- Suppression Joule Rating: 1190 (1020 input / 170 output)
- Efficiency: 96%
Isolator Series UL60601-1 Listed Medical Grade Isolation Transformers offer line isolation continuous noise filtering and enhanced common mode surge suppression. An internal low-impedance isolation transformer component offers 100% isolation from the input AC line. Full UL60601-1 medical-grade listing with hospital-grade plug and outlet receptacles makes Isolator medical-grade transformers ideal for protection of sensitive electronic equipment in patient-care areas. Faraday shield reduces the cumulative leakage current of the Isolator and connected equipment to levels less than 100 microamps. Secondary neutral-to-ground bonding virtually eliminates common mode noise providing an isolated neutral-ground reference for sensitive equipment and an inexpensive alternative to dedicated circuits and site electrical upgrades. Removes EMI/RFI noise utility switching transients and harmonics generated by other on-site loads and utility or lightning related surge conditions. Additional surge suppression components placed at the line input and output combined with full line isolation offer continuous filtering of a full range of power line noise in all modes. Active transformer filtering provides continuous common-mode noise rejection with no wearable parts. Unique ability to reduce surges in the worst of power environments to harmless levels. Reduces 6000V IEE
- Isolator IS1800HG 6 outlets Transformer
- IS1800HG Isolation Transformer
- NEMA5-15P replacement plug
- User manual with warranty information
- UL
- cUL
Out Of Stock
Update
Tripp Lite Isolator Series 120V 1800W UL 60601-1 Medical-Grade Isolation Transformer with 6 Hospital-Grade Outlets - 1800W - 120V AC
Manufacturer : Tripp Lite by Eaton
Manufacturer Part No : IS1800HG
Features
- Complete line isolation noise filtering and surge suppression; ideal for sensitive equipment
- 1800 watts 6 outlets 10-ft. power cord
- Hospital-grade plug and receptacles
- Leakage current less than 100 microamps
- Compliant with the Federal Trade Agreements Act (TAA) for GSA Schedule purchases
Product Details
- Hospital Grade Outlets and Plug
- 20A circuit breaker
- Total Harmonic Distortion: Less than 1%
- Rugged all-metal unit housing
- Cooling Method: Convection
- Noise Suppression Rating: 35-65 DB
- Suppression Joule Rating: 1190 (1020 input / 170 output)
- Efficiency: 96%
Isolator Series UL60601-1 Listed Medical Grade Isolation Transformers offer line isolation continuous noise filtering and enhanced common mode surge suppression. An internal low-impedance isolation transformer component offers 100% isolation from the input AC line. Full UL60601-1 medical-grade listing with hospital-grade plug and outlet receptacles makes Isolator medical-grade transformers ideal for protection of sensitive electronic equipment in patient-care areas. Faraday shield reduces the cumulative leakage current of the Isolator and connected equipment to levels less than 100 microamps. Secondary neutral-to-ground bonding virtually eliminates common mode noise providing an isolated neutral-ground reference for sensitive equipment and an inexpensive alternative to dedicated circuits and site electrical upgrades. Removes EMI/RFI noise utility switching transients and harmonics generated by other on-site loads and utility or lightning related surge conditions. Additional surge suppression components placed at the line input and output combined with full line isolation offer continuous filtering of a full range of power line noise in all modes. Active transformer filtering provides continuous common-mode noise rejection with no wearable parts. Unique ability to reduce surges in the worst of power environments to harmless levels. Reduces 6000V IEE
- Isolator IS1800HG 6 outlets Transformer
- IS1800HG Isolation Transformer
- NEMA5-15P replacement plug
- User manual with warranty information
- UL
- cUL
Recently Viewed
We’re a veteran-owned small business with full-stack expertise. We’ll help you design, coordinate, and manage technology solutions that will drive your business forward.
- About Us
- Contact Us
- My Account
- Prospective Investors
Quick Links
Contracts
Contact Us
-
6402 Corporate Dr, Suite 103,
Indianapolis, IN 46278 - (317) 243-1750
- sales@tekmentum.com
- Mon-Fri: 8:00am-5:00pm
© 2005-2023, Tekmentum. All Rights Reserved. A KPaul, LLC Company.
- Choosing a selection results in a full page refresh.
- Opens in a new window.