Tripp Lite Isolator Series 120V 250W UL 60601-1 Medical-Grade Isolation Transformer with 2 Hospital-Grade Outlets

Tripp Lite Isolator Series 120V 250W UL 60601-1 Medical-Grade Isolation Transformer with 2 Hospital-Grade Outlets

SKU: 10181927      MFR: Tripp Lite by Eaton

GTIN: 37332116208

Product Description

Tripp Lite Isolator Series 120V 250W UL 60601-1 Medical-Grade Isolation Transformer with 2 Hospital-Grade Outlets - 250W - 120V AC - 120V AC

Manufacturer : Tripp Lite by Eaton

Manufacturer Part No : IS250HG

Features

  • Complete line isolation noise filtering and surge suppression; ideal for sensitive equipment
  • 250 watts 2 outlets 6-ft. power cord
  • Hospital-grade plug and receptacles
  • Leakage current less than 100 microamps
  • Compliant with the Federal Trade Agreements Act (TAA) for GSA Schedule purchases

Product Details

Output Receptacle TypeNEMA 5-15R
TAA CompliantYes
Output Receptacle Detail2 x NEMA 5-15R
Maximum Line Current2.10 A
Country of OriginTaiwan
Height4.5"
Width4.8"
Depth7.8"
Manufacturer Part NumberIS250HG
Package Contents
  • IS250HG
  • IS250HG Isolation Transformer
  • Instruction manual with warranty information
Product TypeIsolation Transformer
Additional Information
  • Transformer Type: Medical grade low impedance transformer-based line isolation transformer
  • Removes EMI/RFI noise utility switching transients load-generated harmonics and ground loops
  • Reduces 6000V IEEE587 Cat A&B ring wave and combination wave test surges to only 0.5V common mode
  • Suppression Joule Rating: 680 (510 input/170 output)
  • Leakage Current: As low as 100 microamps
  • Noise Suppression Rating: 35 to 65 DB
  • Total Harmonic Distortion: Less than 1%
  • Over Current Protection: 2A circuit breaker
  • Cooling Method: Convection
  • Efficiency: 96%
  • Let-through Voltage (Ring Wave):
  • L-N: 20 V
  • L-G: 20 V
  • N-G: 0.5 V
  • Let-through Voltage (Combination Wave):
  • L-N: 250 V
  • L-G: 250 V
  • N-G: 0.5 V
Marketing Information

Isolator Series UL60601-1 Listed Medical Grade Isolation Transformers offer line isolation continuous noise filtering and enhanced common mode surge suppression. An internal low-impedance isolation transformer component offers 100% isolation from the input AC line. Full UL60601-1 medical-grade listing with hospital-grade plug and outlet receptacles makes Isolator medical-grade transformers ideal for protection of sensitive electronic equipment in patient-care areas. Faraday shield reduces the cumulative leakage current of the Isolator and connected equipment to levels less than 100 microamps. Secondary neutral-to-ground bonding virtually eliminates common mode noise providing an isolated neutral-ground reference for sensitive equipment and an inexpensive alternative to dedicated circuits and site electrical upgrades. Removes EMI/RFI noise utility switching transients and harmonics generated by other on-site loads and utility or lightning related surge conditions. Additional surge suppression components placed at the line input and output combined with full line isolation offer continuous filtering of a full range of power line noise in all modes. Active transformer filtering provides continuous common-mode noise rejection with no wearable parts. Unique ability to reduce surges in the worst of power environments to harmless levels. Reduces 6000V IEE

Manufacturer Website Addresshttps://tripplite.eaton.com/
Output Voltage120 V AC
Input Voltage120 V AC
Limited Warranty2 Year
Certifications & Standards
  • cUL
  • UL 2601-1
  • UL (UL Series AGIS250YWN)
ManufacturerTripp Lite by Eaton
Form FactorTower
Output ReceptaclesNEMA 5-15R
Product NameIsolator IS250HG Isolation Transformer
Product ModelIS250HG
Power Rating250 VA
Brand NameTripp Lite
View full details
Regular price $390.99 USD
Regular price Sale price $390.99
Sale Sold out

Dropship


Update

   

Shipping calculated at checkout.

Tripp Lite Isolator Series 120V 250W UL 60601-1 Medical-Grade Isolation Transformer with 2 Hospital-Grade Outlets - 250W - 120V AC - 120V AC

Manufacturer : Tripp Lite by Eaton

Manufacturer Part No : IS250HG

Features

  • Complete line isolation noise filtering and surge suppression; ideal for sensitive equipment
  • 250 watts 2 outlets 6-ft. power cord
  • Hospital-grade plug and receptacles
  • Leakage current less than 100 microamps
  • Compliant with the Federal Trade Agreements Act (TAA) for GSA Schedule purchases

Product Details

Output Receptacle TypeNEMA 5-15R
TAA CompliantYes
Output Receptacle Detail2 x NEMA 5-15R
Maximum Line Current2.10 A
Country of OriginTaiwan
Height4.5"
Width4.8"
Depth7.8"
Manufacturer Part NumberIS250HG
Package Contents
  • IS250HG
  • IS250HG Isolation Transformer
  • Instruction manual with warranty information
Product TypeIsolation Transformer
Additional Information
  • Transformer Type: Medical grade low impedance transformer-based line isolation transformer
  • Removes EMI/RFI noise utility switching transients load-generated harmonics and ground loops
  • Reduces 6000V IEEE587 Cat A&B ring wave and combination wave test surges to only 0.5V common mode
  • Suppression Joule Rating: 680 (510 input/170 output)
  • Leakage Current: As low as 100 microamps
  • Noise Suppression Rating: 35 to 65 DB
  • Total Harmonic Distortion: Less than 1%
  • Over Current Protection: 2A circuit breaker
  • Cooling Method: Convection
  • Efficiency: 96%
  • Let-through Voltage (Ring Wave):
  • L-N: 20 V
  • L-G: 20 V
  • N-G: 0.5 V
  • Let-through Voltage (Combination Wave):
  • L-N: 250 V
  • L-G: 250 V
  • N-G: 0.5 V
Marketing Information

Isolator Series UL60601-1 Listed Medical Grade Isolation Transformers offer line isolation continuous noise filtering and enhanced common mode surge suppression. An internal low-impedance isolation transformer component offers 100% isolation from the input AC line. Full UL60601-1 medical-grade listing with hospital-grade plug and outlet receptacles makes Isolator medical-grade transformers ideal for protection of sensitive electronic equipment in patient-care areas. Faraday shield reduces the cumulative leakage current of the Isolator and connected equipment to levels less than 100 microamps. Secondary neutral-to-ground bonding virtually eliminates common mode noise providing an isolated neutral-ground reference for sensitive equipment and an inexpensive alternative to dedicated circuits and site electrical upgrades. Removes EMI/RFI noise utility switching transients and harmonics generated by other on-site loads and utility or lightning related surge conditions. Additional surge suppression components placed at the line input and output combined with full line isolation offer continuous filtering of a full range of power line noise in all modes. Active transformer filtering provides continuous common-mode noise rejection with no wearable parts. Unique ability to reduce surges in the worst of power environments to harmless levels. Reduces 6000V IEE

Manufacturer Website Addresshttps://tripplite.eaton.com/
Output Voltage120 V AC
Input Voltage120 V AC
Limited Warranty2 Year
Certifications & Standards
  • cUL
  • UL 2601-1
  • UL (UL Series AGIS250YWN)
ManufacturerTripp Lite by Eaton
Form FactorTower
Output ReceptaclesNEMA 5-15R
Product NameIsolator IS250HG Isolation Transformer
Product ModelIS250HG
Power Rating250 VA
Brand NameTripp Lite