Skip to product information
1 of 7

Tripp Lite Isolator Series 120V 500W UL 60601-1 Medical-Grade Isolation Transformer with 4 Hospital-Grade Outlets

Tripp Lite Isolator Series 120V 500W UL 60601-1 Medical-Grade Isolation Transformer with 4 Hospital-Grade Outlets

SKU: 10195274      MFR: Tripp Lite by Eaton

GTIN: 37332115898

Product Description

Tripp Lite Isolator Series 120V 500W UL 60601-1 Medical-Grade Isolation Transformer with 4 Hospital-Grade Outlets - Receptacles: 4 x NEMA 5-15R - 680J

Manufacturer : Tripp Lite by Eaton

Manufacturer Part No : IS500HG

Features

  • Complete line isolation noise filtering and surge suppression; ideal for sensitive equipment
  • 500 watts 4 outlets 10-ft. power cord
  • Hospital-grade plug and receptacles
  • Leakage current less than 100 micoramps
  • Compliant with the Federal Trade Agreements Act (TAA) for GSA Schedule purchases

Product Details

Package Contents
  • IS500HG Isolation Transformer
  • Instruction manual with warranty information
Additional Information
  • Tripp Lite's IS500HG Hospital Grade isolation transformer offers line isolation continuous noise filtering and enhanced common mode surge suppression.
  • Internal low-impedence isolation transformer with Faraday shield offers 100% isolation from the input AC line
  • Full UL2601-1 medical grade listing with hospital-grade plug and outlet receptacles makes Isolator Hospital Grade transformers ideal for the protection of sensitive electronic equipment in patient-care areas.
  • Reduces the cumulative leakage current of the Isolator and connected equipment to levels below 300 microamps.
  • Secondary neutral to ground bonding eliminates common mode noise providing an isolated ground reference for sensitive equipment
  • Serves as an inexpensive alternative to the installation of dedicated circuits and site electrical upgrades
  • Removes EMI/RFI noise utility switching transients load generated harmonics and ground loops
  • Additional surge suppression components placed at the line input and output combined with full line isolation offers continuous filtering of a full range of power line noise in all modes
  • Active transformer filtering offers continuous common-mode noise rejection with no wearable parts uniquely able to reduce surges in the worst of power environments to harmless levels
  • Reduces 6000V IEEE587 Cat A&B ring wave and combination wave test surges to only 0.5V common mode
  • Includes 4 widely spaced NEMA5-15R hospital grade output receptacles a 10-ft power cord hospital grade input plug circuit breaker overload protection and lighted power switch.
  • Rugged all-metal unit housing ships ready for upright tower placement in any industrial medical office or network environment
  • 2-year limited product warranty
Manufacturer Website Addresshttps://tripplite.eaton.com/
Input Voltage120 V AC
Manufacturer Part NumberIS500HG
Product TypeSurge Suppressor/Protector
ManufacturerTripp Lite by Eaton
Marketing InformationIsolator Series UL60601-1 Listed Medical Grade Isolation Transformers offer line isolation continuous noise filtering and enhanced common mode surge suppression. An internal low-impedance isolation transformer component offers 100% isolation from the input AC line. Full UL60601-1 medical-grade listing with hospital-grade plug and outlet receptacles makes Isolator medical-grade transformers ideal for protection of sensitive electronic equipment in patient-care areas. Faraday shield reduces the cumulative leakage current of the Isolator and connected equipment to levels less than 100 microamps. Secondary neutral-to-ground bonding virtually eliminates common mode noise providing an isolated neutral-ground reference for sensitive equipment and an inexpensive alternative to dedicated circuits and site electrical upgrades. Removes EMI/RFI noise utility switching transients and harmonics generated by other on-site loads and utility or lightning related surge conditions. Active transformer filtering provides continuous common-mode noise rejection with no wearable parts. Unique ability to reduce surges in the worst of power environments to harmless levels. Reduces 6000V IEEE587 Cat A&B ring wave and combination wave test surges to only 0.5V common mode. Model IS500HG includes 4 widely spaced NEMA 5-15R hospital-grade output receptacles a 10-ft. power cord hospital-grade input plug circuit breaker overload protection and lighted power switch. Rugged all-metal unit ships ready for placement in any industrial medical office or network environment.
Weight (Approximate)22.20 lb
Output Voltage120 V AC
Limited Warranty2 Year
Brand NameTripp Lite
Plug/Connector TypeNEMA 5-15P
Country of OriginTaiwan
Receptacles4 x NEMA 5-15R
Surge Energy Rating680 J
Product LineYes
Product NameIS500HG
Certifications & StandardsUL (UL Series AGIS500YWN) cUL
TAA CompliantYes
Power Cord/Cable Length10 ft
Product FamilyYes
Maximum Line Current4.20 A
View full details
Regular price $538.99 USD
Regular price Sale price $538.99
Sale Sold out

Dropship


Update

   

Shipping calculated at checkout.

Tripp Lite Isolator Series 120V 500W UL 60601-1 Medical-Grade Isolation Transformer with 4 Hospital-Grade Outlets - Receptacles: 4 x NEMA 5-15R - 680J

Manufacturer : Tripp Lite by Eaton

Manufacturer Part No : IS500HG

Features

  • Complete line isolation noise filtering and surge suppression; ideal for sensitive equipment
  • 500 watts 4 outlets 10-ft. power cord
  • Hospital-grade plug and receptacles
  • Leakage current less than 100 micoramps
  • Compliant with the Federal Trade Agreements Act (TAA) for GSA Schedule purchases

Product Details

Package Contents
  • IS500HG Isolation Transformer
  • Instruction manual with warranty information
Additional Information
  • Tripp Lite's IS500HG Hospital Grade isolation transformer offers line isolation continuous noise filtering and enhanced common mode surge suppression.
  • Internal low-impedence isolation transformer with Faraday shield offers 100% isolation from the input AC line
  • Full UL2601-1 medical grade listing with hospital-grade plug and outlet receptacles makes Isolator Hospital Grade transformers ideal for the protection of sensitive electronic equipment in patient-care areas.
  • Reduces the cumulative leakage current of the Isolator and connected equipment to levels below 300 microamps.
  • Secondary neutral to ground bonding eliminates common mode noise providing an isolated ground reference for sensitive equipment
  • Serves as an inexpensive alternative to the installation of dedicated circuits and site electrical upgrades
  • Removes EMI/RFI noise utility switching transients load generated harmonics and ground loops
  • Additional surge suppression components placed at the line input and output combined with full line isolation offers continuous filtering of a full range of power line noise in all modes
  • Active transformer filtering offers continuous common-mode noise rejection with no wearable parts uniquely able to reduce surges in the worst of power environments to harmless levels
  • Reduces 6000V IEEE587 Cat A&B ring wave and combination wave test surges to only 0.5V common mode
  • Includes 4 widely spaced NEMA5-15R hospital grade output receptacles a 10-ft power cord hospital grade input plug circuit breaker overload protection and lighted power switch.
  • Rugged all-metal unit housing ships ready for upright tower placement in any industrial medical office or network environment
  • 2-year limited product warranty
Manufacturer Website Addresshttps://tripplite.eaton.com/
Input Voltage120 V AC
Manufacturer Part NumberIS500HG
Product TypeSurge Suppressor/Protector
ManufacturerTripp Lite by Eaton
Marketing InformationIsolator Series UL60601-1 Listed Medical Grade Isolation Transformers offer line isolation continuous noise filtering and enhanced common mode surge suppression. An internal low-impedance isolation transformer component offers 100% isolation from the input AC line. Full UL60601-1 medical-grade listing with hospital-grade plug and outlet receptacles makes Isolator medical-grade transformers ideal for protection of sensitive electronic equipment in patient-care areas. Faraday shield reduces the cumulative leakage current of the Isolator and connected equipment to levels less than 100 microamps. Secondary neutral-to-ground bonding virtually eliminates common mode noise providing an isolated neutral-ground reference for sensitive equipment and an inexpensive alternative to dedicated circuits and site electrical upgrades. Removes EMI/RFI noise utility switching transients and harmonics generated by other on-site loads and utility or lightning related surge conditions. Active transformer filtering provides continuous common-mode noise rejection with no wearable parts. Unique ability to reduce surges in the worst of power environments to harmless levels. Reduces 6000V IEEE587 Cat A&B ring wave and combination wave test surges to only 0.5V common mode. Model IS500HG includes 4 widely spaced NEMA 5-15R hospital-grade output receptacles a 10-ft. power cord hospital-grade input plug circuit breaker overload protection and lighted power switch. Rugged all-metal unit ships ready for placement in any industrial medical office or network environment.
Weight (Approximate)22.20 lb
Output Voltage120 V AC
Limited Warranty2 Year
Brand NameTripp Lite
Plug/Connector TypeNEMA 5-15P
Country of OriginTaiwan
Receptacles4 x NEMA 5-15R
Surge Energy Rating680 J
Product LineYes
Product NameIS500HG
Certifications & StandardsUL (UL Series AGIS500YWN) cUL
TAA CompliantYes
Power Cord/Cable Length10 ft
Product FamilyYes
Maximum Line Current4.20 A

Recently Viewed