Product Description
Tripp Lite PDU 7.7kW Single-Phase 200-240V Monitored Automatic Transfer Switch PDU Two 32A IEC309 32A Blue Inputs 1 IEC309 32A Outlet 1U - IEC 60309 32A BLUE (2P+E) - IEC 60309 32A BLUE (2P+E) - 200 V AC 208 V AC 220 V AC 230 V AC 240 V AC - 7.70 kVA - 1U - Horizontal Rackmount
Manufacturer : Tripp Lite by Eaton
Manufacturer Part No : PDUMNH32HVAT
Features
- Two IEC 309 32A Blue (2P+E) inputs w/10 ft. (3 m) cords
- IEC 309 32A Blue (2P+E) outlet for connecting device or 0U PDU
- Automatic transfer switching within 1-5 ms
- Ethernet network interface for remote access
- Digital display with LEDs for real-time status monitoring
Product Details
- HTTP
- HTTPS
- SMTP
- SNMPv1
- SNMPv2
- SNMPv3
- Telnet
- SSH
- FTP
- DHCP
- NTP
Dual 3 meter (10ft) input cords each with IEC 309 32A Blue input plug connect to any two separate primary and secondary input power sources including out-of-phase input sources. The PDU constantly evaluates the power quality of both inputs. To ensure connected equipment remains powered dynamic solid-state (TRIAC) automatic transfer switching allows the PDU to switch to the secondary source within 1-5 milliseconds if the primary source fails or becomes unstable.
Built-in LX Platform network management interface allows remote access to the PDU for power monitoring configuration control and to receive user-configurable notifications. The Java-free LX Platform HTML5-based network interface enables full remote access for PDU status monitoring and email notifications via secure web browser SNMP telnet or SSH. Provides real-time load/current data with billing-grade accuracy (+/- 1 percent). It supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network. Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities. Protocols supported include HTTP HTTPS SMTP SNMPv1 SNMPv2 SNMPv3 telnet SSH FTP DHCP and NTP.
- PDUMNH32HVAT 7.4kW Single-Phase 230V ATS/Monitored PDU
- Rack-Mounting Brackets
- Rear Support Rail Kit
- Owner's Manual
Dropship
Update
Couldn't load pickup availability
![Tripp Lite PDU 7.7kW Single-Phase 200-240V Monitored Automatic Transfer Switch PDU Two 32A IEC309 32A Blue Inputs 1 IEC309 32A Outlet 1U](http://tekmentum.com/cdn/shop/files/1035018037_7e4e5061-d089-4451-9d58-7583de571e28.jpg?v=1698384966&width=1445)
![Tripp Lite PDU 7.7kW Single-Phase 200-240V Monitored Automatic Transfer Switch PDU Two 32A IEC309 32A Blue Inputs 1 IEC309 32A Outlet 1U](http://tekmentum.com/cdn/shop/files/1035018037_4264afc5-8eea-4c04-830f-ee43adf3ffd7.jpg?v=1698384966&width=1445)
![Tripp Lite PDU 7.7kW Single-Phase 200-240V Monitored Automatic Transfer Switch PDU Two 32A IEC309 32A Blue Inputs 1 IEC309 32A Outlet 1U](http://tekmentum.com/cdn/shop/files/1035018037_96523add-d61f-410b-981c-64c44f042ee7.jpg?v=1698384966&width=1445)
![Tripp Lite PDU 7.7kW Single-Phase 200-240V Monitored Automatic Transfer Switch PDU Two 32A IEC309 32A Blue Inputs 1 IEC309 32A Outlet 1U](http://tekmentum.com/cdn/shop/files/1035018037_1c561439-e9d1-492b-8c82-649cf893e030.jpg?v=1698384966&width=1445)
![Tripp Lite PDU 7.7kW Single-Phase 200-240V Monitored Automatic Transfer Switch PDU Two 32A IEC309 32A Blue Inputs 1 IEC309 32A Outlet 1U](http://tekmentum.com/cdn/shop/files/1035018037_5e44e9df-7343-4d68-a58c-dc7b0757164c.jpg?v=1698384966&width=1445)
![Tripp Lite PDU 7.7kW Single-Phase 200-240V Monitored Automatic Transfer Switch PDU Two 32A IEC309 32A Blue Inputs 1 IEC309 32A Outlet 1U](http://tekmentum.com/cdn/shop/files/1035018037_e93568f8-559d-4bde-b2c5-ab8d53075a97.jpg?v=1698384966&width=1445)
![Tripp Lite PDU 7.7kW Single-Phase 200-240V Monitored Automatic Transfer Switch PDU Two 32A IEC309 32A Blue Inputs 1 IEC309 32A Outlet 1U](http://tekmentum.com/cdn/shop/files/1035018037_f0b7ef56-806b-4116-adef-02d68fc2bfaa.jpg?v=1698384966&width=1445)
![Tripp Lite PDU 7.7kW Single-Phase 200-240V Monitored Automatic Transfer Switch PDU Two 32A IEC309 32A Blue Inputs 1 IEC309 32A Outlet 1U](http://tekmentum.com/cdn/shop/files/1035018037_fa8f5da9-e011-44e6-bb90-bc4bc8bd61af.jpg?v=1698384966&width=1445)
Tripp Lite PDU 7.7kW Single-Phase 200-240V Monitored Automatic Transfer Switch PDU Two 32A IEC309 32A Blue Inputs 1 IEC309 32A Outlet 1U - IEC 60309 32A BLUE (2P+E) - IEC 60309 32A BLUE (2P+E) - 200 V AC 208 V AC 220 V AC 230 V AC 240 V AC - 7.70 kVA - 1U - Horizontal Rackmount
Manufacturer : Tripp Lite by Eaton
Manufacturer Part No : PDUMNH32HVAT
Features
- Two IEC 309 32A Blue (2P+E) inputs w/10 ft. (3 m) cords
- IEC 309 32A Blue (2P+E) outlet for connecting device or 0U PDU
- Automatic transfer switching within 1-5 ms
- Ethernet network interface for remote access
- Digital display with LEDs for real-time status monitoring
Product Details
- HTTP
- HTTPS
- SMTP
- SNMPv1
- SNMPv2
- SNMPv3
- Telnet
- SSH
- FTP
- DHCP
- NTP
Dual 3 meter (10ft) input cords each with IEC 309 32A Blue input plug connect to any two separate primary and secondary input power sources including out-of-phase input sources. The PDU constantly evaluates the power quality of both inputs. To ensure connected equipment remains powered dynamic solid-state (TRIAC) automatic transfer switching allows the PDU to switch to the secondary source within 1-5 milliseconds if the primary source fails or becomes unstable.
Built-in LX Platform network management interface allows remote access to the PDU for power monitoring configuration control and to receive user-configurable notifications. The Java-free LX Platform HTML5-based network interface enables full remote access for PDU status monitoring and email notifications via secure web browser SNMP telnet or SSH. Provides real-time load/current data with billing-grade accuracy (+/- 1 percent). It supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network. Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities. Protocols supported include HTTP HTTPS SMTP SNMPv1 SNMPv2 SNMPv3 telnet SSH FTP DHCP and NTP.
- PDUMNH32HVAT 7.4kW Single-Phase 230V ATS/Monitored PDU
- Rack-Mounting Brackets
- Rear Support Rail Kit
- Owner's Manual
Recently Viewed
We’re a veteran-owned small business with full-stack expertise. We’ll help you design, coordinate, and manage technology solutions that will drive your business forward.
- About Us
- Contact Us
- My Account
- Prospective Investors
Quick Links
Contracts
Contact Us
-
6402 Corporate Dr, Suite 103,
Indianapolis, IN 46278 - (317) 243-1750
- sales@tekmentum.com
- Mon-Fri: 8:00am-5:00pm
© 2005-2023, Tekmentum. All Rights Reserved. A KPaul, LLC Company.
- Choosing a selection results in a full page refresh.
- Opens in a new window.