Tripp Lite PDU Hot Swap with Manual ByPass 200-240V 10A 6 C13 2 C14 1URM

Tripp Lite PDU Hot Swap with Manual ByPass 200-240V 10A 6 C13 2 C14 1URM

SKU: 1067697912      MFR: Tripp Lite by Eaton

GTIN: 37332253095

Product Description

Tripp Lite PDU Hot Swap with Manual ByPass 200-240V 10A 6 C13 2 C14 1URM - Manual Bypass - IEC 60320 C14 - 6 x IEC 60320 C13 - 230 V AC - 1U - Horizontal - Wall-mountable Rack-mountable - Hot-swappable

Manufacturer : Tripp Lite by Eaton

Manufacturer Part No : PDUBHV101U

Features

  • Ideal for supporting critical IT equipment that require 24/7/365 uptime
  • Transfers connected components to utility power with no downtime during UPS maintenance
  • Dual C14 inlets support connection to separate UPS and utility input power sources
  • ECO mode saves power by shutting down controlled outlet bank in certain conditions
  • Mounts into 1U of rack space or onto wall using included mounting hardware
  • 2-year limited warranty

Product Details

Product TypePDU
PhaseSingle Phase
Receptacle TypeIEC 60320 C13
Environmentally FriendlyYes
Environmental CertificationRoHS
Output Voltage Range200 V AC - 250 V AC
PDU TypeManual Bypass
Mounting OrientationHorizontal
Power Rating (Watt)2400 W
Receptacle Detail6 x IEC 60320 C13
Plug/Connector Detail2 x IEC 60320 C14
Height1.7"
Width17.2"
Depth3.9"
Rack Height1U
Brand NameTripp Lite
Plug/Connector TypeIEC 60320 C14
Input Voltage Range200 V AC - 250 V AC
Form FactorHot-swappable
Input Current10 A
ManufacturerTripp Lite by Eaton
Product ModelPDUBHV101U
Product NamePDUBHV101U 6-Outlets PDU
Mount TypeWall-mountable
Input Voltage230 V AC
Manufacturer Part NumberPDUBHV101U
Manufacturer Website Addresshttp://www.tripplite.com
Marketing Information

Bypass PDU Recommended for Maintaining Continuous Power During UPS Maintenance
Keeping mission-critical data center equipment operating at its optimal level often means scheduled maintenance. But what if you are unable to afford the costly downtime involved in powering down for regular upkeep? This 200-250V 10A single-phase hot-swap PDU works in conjunction with your UPS system to keep everything running 24/7/365. It allows you to manually transfer connected equipment to utility power via the PDU's bypass switch permitting maintenance or equipment replacement with no interruption of performance.

Features Dual Inputs and a Manual Transfer Switch for Uninterrupted Operation
The PDUBHV101U features two C14 inlets that connect to separate UPS and utility input power sources with user-supplied power cables or the included C13-to-C14 cables. The manual transfer switch allows PDU output power to flow from either input. Flip the switch to Bypass to replace the UPS and flip back to Normal once the maintenance or UPS replacement is complete. Equipment connected to the six C13 outlets will continue to operate without interruption.

Optional ECO Switching Feature Enables Cost-Cutting Power Savings
By enabling the ECO power saving feature you can power off a single bank of five controlled C13 outlets all at once when the device connected to the master C13 outlet is powered off or goes into a low-power consumption mode.

Mounts into 1U of Rack Space or on a Wall
Use the included mounting hardware to install the PDUBHV101U's all-metal housing into 1U of space in an EIA-standard 19-inch rack. You may also use the mounting brackets to secure the PDU to a wall.

Package Contents
  • PDUBHV101U 6-Outlets PDU
  • 2 x C13-to-C14 Power Cables
  • Mounting Hardware
  • Owner's Manual
Limited Warranty2 Year
Weight (Approximate)5.20 lb
View full details
Regular price $211.99 USD
Regular price Sale price $211.99
Sale Sold out

Dropship


Update

   

Shipping calculated at checkout.

Tripp Lite PDU Hot Swap with Manual ByPass 200-240V 10A 6 C13 2 C14 1URM - Manual Bypass - IEC 60320 C14 - 6 x IEC 60320 C13 - 230 V AC - 1U - Horizontal - Wall-mountable Rack-mountable - Hot-swappable

Manufacturer : Tripp Lite by Eaton

Manufacturer Part No : PDUBHV101U

Features

  • Ideal for supporting critical IT equipment that require 24/7/365 uptime
  • Transfers connected components to utility power with no downtime during UPS maintenance
  • Dual C14 inlets support connection to separate UPS and utility input power sources
  • ECO mode saves power by shutting down controlled outlet bank in certain conditions
  • Mounts into 1U of rack space or onto wall using included mounting hardware
  • 2-year limited warranty

Product Details

Product TypePDU
PhaseSingle Phase
Receptacle TypeIEC 60320 C13
Environmentally FriendlyYes
Environmental CertificationRoHS
Output Voltage Range200 V AC - 250 V AC
PDU TypeManual Bypass
Mounting OrientationHorizontal
Power Rating (Watt)2400 W
Receptacle Detail6 x IEC 60320 C13
Plug/Connector Detail2 x IEC 60320 C14
Height1.7"
Width17.2"
Depth3.9"
Rack Height1U
Brand NameTripp Lite
Plug/Connector TypeIEC 60320 C14
Input Voltage Range200 V AC - 250 V AC
Form FactorHot-swappable
Input Current10 A
ManufacturerTripp Lite by Eaton
Product ModelPDUBHV101U
Product NamePDUBHV101U 6-Outlets PDU
Mount TypeWall-mountable
Input Voltage230 V AC
Manufacturer Part NumberPDUBHV101U
Manufacturer Website Addresshttp://www.tripplite.com
Marketing Information

Bypass PDU Recommended for Maintaining Continuous Power During UPS Maintenance
Keeping mission-critical data center equipment operating at its optimal level often means scheduled maintenance. But what if you are unable to afford the costly downtime involved in powering down for regular upkeep? This 200-250V 10A single-phase hot-swap PDU works in conjunction with your UPS system to keep everything running 24/7/365. It allows you to manually transfer connected equipment to utility power via the PDU's bypass switch permitting maintenance or equipment replacement with no interruption of performance.

Features Dual Inputs and a Manual Transfer Switch for Uninterrupted Operation
The PDUBHV101U features two C14 inlets that connect to separate UPS and utility input power sources with user-supplied power cables or the included C13-to-C14 cables. The manual transfer switch allows PDU output power to flow from either input. Flip the switch to Bypass to replace the UPS and flip back to Normal once the maintenance or UPS replacement is complete. Equipment connected to the six C13 outlets will continue to operate without interruption.

Optional ECO Switching Feature Enables Cost-Cutting Power Savings
By enabling the ECO power saving feature you can power off a single bank of five controlled C13 outlets all at once when the device connected to the master C13 outlet is powered off or goes into a low-power consumption mode.

Mounts into 1U of Rack Space or on a Wall
Use the included mounting hardware to install the PDUBHV101U's all-metal housing into 1U of space in an EIA-standard 19-inch rack. You may also use the mounting brackets to secure the PDU to a wall.

Package Contents
  • PDUBHV101U 6-Outlets PDU
  • 2 x C13-to-C14 Power Cables
  • Mounting Hardware
  • Owner's Manual
Limited Warranty2 Year
Weight (Approximate)5.20 lb