Tripp Lite PDU Hot Swap with Manual ByPass 200-240V 16A 5 C13 2 C20 1URM
Tripp Lite PDU Hot Swap with Manual ByPass 200-240V 16A 5 C13 2 C20 1URM
SKU: 1067697913 MFR: Tripp Lite by Eaton
GTIN: 37332262455
Product Description
Tripp Lite PDU Hot Swap with Manual ByPass 200-240V 16A 5 C13 2 C20 1URM - Manual Bypass - IEC 60320 C20 - 5 x IEC 60320 C13 1 x IEC 60320 C19 - 230 V AC - 1U - Horizontal - Wall-mountable Rack-mountable - Hot-swappable
Manufacturer : Tripp Lite by Eaton
Manufacturer Part No : PDUBHV201U
Features
- Ideal for supporting critical IT equipment that require 24/7/365 uptime
- Transfers connected components to utility power with no downtime during UPS maintenance
- Dual C20 inlets support connection to separate UPS and utility input power sources
- ECO mode saves power by shutting down controlled outlet bank in certain conditions
- Mounts into 1U of rack space or onto wall using included mounting hardware
- 2-year limited warranty
Product Details
Bypass PDU Recommended for Maintaining Continuous Power During UPS Maintenance
Keeping mission-critical data center equipment operating at its optimal level often means scheduled maintenance. But what if you are unable to afford the costly downtime involved in powering down for regular upkeep? This 200-250V 16A single-phase hot-swap PDU works in conjunction with your UPS system to keep everything running 24/7/365. It allows you to manually transfer connected equipment to utility power via the PDU's bypass switch permitting maintenance or equipment replacement with no interruption of performance.
Features Dual Inputs and a Manual Transfer Switch for Uninterrupted Operation
The PDUBHV201U features two C20 inlets that connect to separate UPS and utility input power sources with user-supplied power cables or the included C19-to-C20 cables. The manual transfer switch allows PDU output power to flow from either input. Flip the switch to Bypass to replace the UPS and flip back to Normal once the maintenance or UPS replacement is complete. Equipment connected to the outlets will continue to operate without interruption.
Optional ECO Switching Feature Enables Cost-Cutting Power Savings
By enabling the ECO power saving feature you can power off a single bank of four controlled C13 outlets all at once when the devices connected to the master C13 and C19 outlets are powered off or go into a low-power consumption mode.
Mounts into 1U of Rack Space or on a Wall
Use the included mounting hardware to install the PDUBHV201U's all-metal housing into 1U of space in an EIA-standard 19-inch rack. You may also use the mounting brackets to secure the PDU to a wall.
- PDUBHV201U 6-Outlets PDU
- 2 x C19-to-C20 Power Cables
- Mounting Hardware
- Owner's Manual
Out Of Stock
Update
Couldn't load pickup availability
![Tripp Lite PDU Hot Swap with Manual ByPass 200-240V 16A 5 C13 2 C20 1URM](http://tekmentum.com/cdn/shop/files/1067697913.jpg?v=1696634824&width=1445)
![Tripp Lite PDU Hot Swap with Manual ByPass 200-240V 16A 5 C13 2 C20 1URM](http://tekmentum.com/cdn/shop/files/1067697913_fd956390-b498-4188-a099-bd11bf9edfbc.jpg?v=1698521753&width=1445)
![Tripp Lite PDU Hot Swap with Manual ByPass 200-240V 16A 5 C13 2 C20 1URM](http://tekmentum.com/cdn/shop/files/1067697913_9aeab296-0ba3-4654-87b7-4a687b19ec68.jpg?v=1698521792&width=1445)
![Tripp Lite PDU Hot Swap with Manual ByPass 200-240V 16A 5 C13 2 C20 1URM](http://tekmentum.com/cdn/shop/files/1067697913_1c2ee726-4d4a-4718-b350-28a50bcc8d35.jpg?v=1698521795&width=1445)
![Tripp Lite PDU Hot Swap with Manual ByPass 200-240V 16A 5 C13 2 C20 1URM](http://tekmentum.com/cdn/shop/files/1067697913_2a318c28-1cba-4f50-b6d0-2fd33de8fadf.jpg?v=1698521799&width=1445)
Tripp Lite PDU Hot Swap with Manual ByPass 200-240V 16A 5 C13 2 C20 1URM - Manual Bypass - IEC 60320 C20 - 5 x IEC 60320 C13 1 x IEC 60320 C19 - 230 V AC - 1U - Horizontal - Wall-mountable Rack-mountable - Hot-swappable
Manufacturer : Tripp Lite by Eaton
Manufacturer Part No : PDUBHV201U
Features
- Ideal for supporting critical IT equipment that require 24/7/365 uptime
- Transfers connected components to utility power with no downtime during UPS maintenance
- Dual C20 inlets support connection to separate UPS and utility input power sources
- ECO mode saves power by shutting down controlled outlet bank in certain conditions
- Mounts into 1U of rack space or onto wall using included mounting hardware
- 2-year limited warranty
Product Details
Bypass PDU Recommended for Maintaining Continuous Power During UPS Maintenance
Keeping mission-critical data center equipment operating at its optimal level often means scheduled maintenance. But what if you are unable to afford the costly downtime involved in powering down for regular upkeep? This 200-250V 16A single-phase hot-swap PDU works in conjunction with your UPS system to keep everything running 24/7/365. It allows you to manually transfer connected equipment to utility power via the PDU's bypass switch permitting maintenance or equipment replacement with no interruption of performance.
Features Dual Inputs and a Manual Transfer Switch for Uninterrupted Operation
The PDUBHV201U features two C20 inlets that connect to separate UPS and utility input power sources with user-supplied power cables or the included C19-to-C20 cables. The manual transfer switch allows PDU output power to flow from either input. Flip the switch to Bypass to replace the UPS and flip back to Normal once the maintenance or UPS replacement is complete. Equipment connected to the outlets will continue to operate without interruption.
Optional ECO Switching Feature Enables Cost-Cutting Power Savings
By enabling the ECO power saving feature you can power off a single bank of four controlled C13 outlets all at once when the devices connected to the master C13 and C19 outlets are powered off or go into a low-power consumption mode.
Mounts into 1U of Rack Space or on a Wall
Use the included mounting hardware to install the PDUBHV201U's all-metal housing into 1U of space in an EIA-standard 19-inch rack. You may also use the mounting brackets to secure the PDU to a wall.
- PDUBHV201U 6-Outlets PDU
- 2 x C19-to-C20 Power Cables
- Mounting Hardware
- Owner's Manual
Recently Viewed
We’re a veteran-owned small business with full-stack expertise. We’ll help you design, coordinate, and manage technology solutions that will drive your business forward.
- About Us
- Contact Us
- My Account
- Prospective Investors
Quick Links
Contracts
Contact Us
-
6402 Corporate Dr, Suite 103,
Indianapolis, IN 46278 - (317) 243-1750
- sales@tekmentum.com
- Mon-Fri: 8:00am-5:00pm
© 2005-2023, Tekmentum. All Rights Reserved. A KPaul, LLC Company.
- Choosing a selection results in a full page refresh.
- Opens in a new window.