Tripp Lite PDU Metered ATS 120V 20A 5-15/20R 16 Outlet L5-20P Horizontal 1U
Tripp Lite PDU Metered ATS 120V 20A 5-15/20R 16 Outlet L5-20P Horizontal 1U
SKU: 1010546934 MFR: Tripp Lite by Eaton
GTIN: 037332126665
Product Description
Tripp Lite PDU Metered ATS 120V 20A 5-15/20R 16 Outlet L5-20P Horizontal 1U - 16 x NEMA 5-15/20R - 2.4kVA - 1U Rack-mountable
Manufacturer : Tripp Lite by Eaton
Manufacturer Part No : PDUMH20AT
Features
- Single phase 20A 120V Auto Transfer Switch / ATS PDU
- Enables redundant A/B power option for single-corded network devices
- Separate primary & secondary inputs connect to any two compatible power sources
- 1U horizontal rackmount; 2 NEMA L5-20P / 5-20P inputs; 16 5-15/20R outlets
Product Details
- 60950
- Class A
- RoHS Complaint
- Optional Automatic Transfer Switch (ATS) function enables setup for hot-swappable UPS maintenance bypass
- Dual UPS protection or dual AC input redundancy for critical single-corded network hardware
- Slot for optional SNMPWEBCARD accessory to enable remote individual outlet control over IP
Tripp Lite Metered ATS / Auto Transfer Switch provides a redundant power option for single-corded network devices. Dual input cords support separate connection to PRIMARY and SECONDARY power sources. If the primary power source becomes unstable or fails altogether the ATS will switch over to the secondary power source until the primary input is restored and stable. Enables fault tolerant hot-swappable UPS protection when used with a single UPS and fully redundant UPS protection when each cord is connected to a separate UPS system. In a two-UPS environment the primary input cable must be supported by a full time sine wave UPS with zero transfer time. On-board ATS processor constantly evaluates power quality on both input sources to prevent transfer to the secondary source when unavailable or of lower quality than the primary source. Front input LED's display primary or secondary power availability.
- PDUMH20AT PDU Metered ATS 120V 20A 16 Outlet
- PDU with attached L5-20P input power cord
- Detachable C19 to NEMA L5-20P 12 ft/3.6m power cord for optional secondary input
- Two NEMA L5-20R to NEMA 5-20P plug adapters
- User manual with warranty information
Dropship
Update
Couldn't load pickup availability
![Tripp Lite PDU Metered ATS 120V 20A 5-15/20R 16 Outlet L5-20P Horizontal 1U](http://tekmentum.com/cdn/shop/files/1010546934.jpg?v=1695156274&width=1445)
![Tripp Lite PDU Metered ATS 120V 20A 5-15/20R 16 Outlet L5-20P Horizontal 1U](http://tekmentum.com/cdn/shop/files/1010546934_beb4447d-7ea8-4288-a109-01f62dbfba2c.jpg?v=1698356650&width=1445)
![Tripp Lite PDU Metered ATS 120V 20A 5-15/20R 16 Outlet L5-20P Horizontal 1U](http://tekmentum.com/cdn/shop/files/1010546934_8d113765-19b9-476c-b9f3-bcf04589d886.jpg?v=1698356652&width=1445)
Tripp Lite PDU Metered ATS 120V 20A 5-15/20R 16 Outlet L5-20P Horizontal 1U - 16 x NEMA 5-15/20R - 2.4kVA - 1U Rack-mountable
Manufacturer : Tripp Lite by Eaton
Manufacturer Part No : PDUMH20AT
Features
- Single phase 20A 120V Auto Transfer Switch / ATS PDU
- Enables redundant A/B power option for single-corded network devices
- Separate primary & secondary inputs connect to any two compatible power sources
- 1U horizontal rackmount; 2 NEMA L5-20P / 5-20P inputs; 16 5-15/20R outlets
Product Details
- 60950
- Class A
- RoHS Complaint
- Optional Automatic Transfer Switch (ATS) function enables setup for hot-swappable UPS maintenance bypass
- Dual UPS protection or dual AC input redundancy for critical single-corded network hardware
- Slot for optional SNMPWEBCARD accessory to enable remote individual outlet control over IP
Tripp Lite Metered ATS / Auto Transfer Switch provides a redundant power option for single-corded network devices. Dual input cords support separate connection to PRIMARY and SECONDARY power sources. If the primary power source becomes unstable or fails altogether the ATS will switch over to the secondary power source until the primary input is restored and stable. Enables fault tolerant hot-swappable UPS protection when used with a single UPS and fully redundant UPS protection when each cord is connected to a separate UPS system. In a two-UPS environment the primary input cable must be supported by a full time sine wave UPS with zero transfer time. On-board ATS processor constantly evaluates power quality on both input sources to prevent transfer to the secondary source when unavailable or of lower quality than the primary source. Front input LED's display primary or secondary power availability.
- PDUMH20AT PDU Metered ATS 120V 20A 16 Outlet
- PDU with attached L5-20P input power cord
- Detachable C19 to NEMA L5-20P 12 ft/3.6m power cord for optional secondary input
- Two NEMA L5-20R to NEMA 5-20P plug adapters
- User manual with warranty information
Recently Viewed
We’re a veteran-owned small business with full-stack expertise. We’ll help you design, coordinate, and manage technology solutions that will drive your business forward.
- About Us
- Contact Us
- My Account
- Prospective Investors
Quick Links
Contracts
Contact Us
-
6402 Corporate Dr, Suite 103,
Indianapolis, IN 46278 - (317) 243-1750
- sales@tekmentum.com
- Mon-Fri: 8:00am-5:00pm
© 2005-2023, Tekmentum. All Rights Reserved. A KPaul, LLC Company.
- Choosing a selection results in a full page refresh.
- Opens in a new window.