Product Description

Tripp Lite PDU Switched 208V - 240V 30A 8 C13; 6 C19 L6-30P Horizontal 2URM - 14 - 2U Rack-mountable

Manufacturer : Tripp Lite by Eaton

Manufacturer Part No : PDUMH30HV19NET

Features

  • 5.8kW 208/240V Switched 30A PDU 2U horizontal rackmount format
  • Built-in Java-free LX Platform interface for 24/7 remote access
  • Reports voltage frequency & load level via ethernet interface
  • Visual current meter Reversible housing
  • NEMA L6-30P input with attached 15 ft. / 4.5m line cord
  • 14 switched outlets (8 C13 6 C19) with cord retention brackets
  • Temperature humidity and contact closure monitoring options
  • TAA Compliant

Product Details

Rack Height2U
Brand NameTripp Lite
Plug/Connector TypeNEMA L6-30P
Input Voltage Range208 V AC - 240 V AC
Management

Protocols:

  • HTTP
  • HTTPS
  • PowerAlert Network Management System
  • SMTP
  • SNMPv1
  • SNMPv2
  • Telnet
  • FTP
  • DHCP
  • BOOTP
  • NTP
ManufacturerTripp Lite by Eaton
Product ModelPDUMH30HV19NET
Product NamePDUMH30HV19NET PDU Switched 208V - 240V 30A 14 Outlet
Mount TypeRack-mountable
Input Voltage230 V AC
Manufacturer Part NumberPDUMH30HV19NET
Manufacturer Website Addresshttp://www.tripplite.com
Marketing InformationTripp Lite single phase Switched PDU / Power Distribution Unit offers advanced network control and monitoring with the ability to turn on turn off recycle or lock-out power to each individual receptacle monitor site electrical conditions and remotely monitor output power consumption. Built-in LX Platform network management interface card. The Java-free LX Platform HTML5-based network interface enables full remote access for PDU status monitoring and email notifications via secure web browser SNMP telnet or SSH. It supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network. Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities. Protocols supported include HTTP HTTPS SMTP SNMPv1 SNMPv2 SNMPv3 telnet SSH FTP DHCP and NTP. Individually switched outlets can be controlled in real-time to remotely reboot unresponsive network hardware or be custom programmed for user-defined power-up and power-down sequences to ensure proper startup of interdependent IT systems and prevent inrush-related overloads as network equipment is first energized. Unused PDU outlets can be electronically locked off to prevent the connection of unauthorized hardware. PDU output current consumption in amps is continuously displayed locally via visual meter and remotely via web/network interface to warn of potential overloads before critical IT mains or branch breakers trip.
Package Contents
  • PDUMH30HV19NET PDU Switched 208V - 240V 30A 14 Outlet
  • Installable 2U Mounting Brackets
Limited Warranty2 Year
Additional Information

Output Receptacles:

  • 8 x C13
  • 6 x C19
Output Voltage208 V AC
Output Voltage240 V AC
Weight (Approximate)13.80 lb
Depth12.5"
Width17.5"
Height3.5"
Country of OriginTaiwan
Receptacle Detail14
PDU TypeSwitched
TAA CompliantYes
Environmental CertificationRoHS
Environmentally FriendlyYes
Product TypePDU
View full details
Regular price $1,331.99 USD
Regular price Sale price $1,331.99
Sale Sold out

Dropship


Update

   

Shipping calculated at checkout.

Tripp Lite PDU Switched 208V - 240V 30A 8 C13; 6 C19 L6-30P Horizontal 2URM - 14 - 2U Rack-mountable

Manufacturer : Tripp Lite by Eaton

Manufacturer Part No : PDUMH30HV19NET

Features

  • 5.8kW 208/240V Switched 30A PDU 2U horizontal rackmount format
  • Built-in Java-free LX Platform interface for 24/7 remote access
  • Reports voltage frequency & load level via ethernet interface
  • Visual current meter Reversible housing
  • NEMA L6-30P input with attached 15 ft. / 4.5m line cord
  • 14 switched outlets (8 C13 6 C19) with cord retention brackets
  • Temperature humidity and contact closure monitoring options
  • TAA Compliant

Product Details

Rack Height2U
Brand NameTripp Lite
Plug/Connector TypeNEMA L6-30P
Input Voltage Range208 V AC - 240 V AC
Management

Protocols:

  • HTTP
  • HTTPS
  • PowerAlert Network Management System
  • SMTP
  • SNMPv1
  • SNMPv2
  • Telnet
  • FTP
  • DHCP
  • BOOTP
  • NTP
ManufacturerTripp Lite by Eaton
Product ModelPDUMH30HV19NET
Product NamePDUMH30HV19NET PDU Switched 208V - 240V 30A 14 Outlet
Mount TypeRack-mountable
Input Voltage230 V AC
Manufacturer Part NumberPDUMH30HV19NET
Manufacturer Website Addresshttp://www.tripplite.com
Marketing InformationTripp Lite single phase Switched PDU / Power Distribution Unit offers advanced network control and monitoring with the ability to turn on turn off recycle or lock-out power to each individual receptacle monitor site electrical conditions and remotely monitor output power consumption. Built-in LX Platform network management interface card. The Java-free LX Platform HTML5-based network interface enables full remote access for PDU status monitoring and email notifications via secure web browser SNMP telnet or SSH. It supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network. Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities. Protocols supported include HTTP HTTPS SMTP SNMPv1 SNMPv2 SNMPv3 telnet SSH FTP DHCP and NTP. Individually switched outlets can be controlled in real-time to remotely reboot unresponsive network hardware or be custom programmed for user-defined power-up and power-down sequences to ensure proper startup of interdependent IT systems and prevent inrush-related overloads as network equipment is first energized. Unused PDU outlets can be electronically locked off to prevent the connection of unauthorized hardware. PDU output current consumption in amps is continuously displayed locally via visual meter and remotely via web/network interface to warn of potential overloads before critical IT mains or branch breakers trip.
Package Contents
  • PDUMH30HV19NET PDU Switched 208V - 240V 30A 14 Outlet
  • Installable 2U Mounting Brackets
Limited Warranty2 Year
Additional Information

Output Receptacles:

  • 8 x C13
  • 6 x C19
Output Voltage208 V AC
Output Voltage240 V AC
Weight (Approximate)13.80 lb
Depth12.5"
Width17.5"
Height3.5"
Country of OriginTaiwan
Receptacle Detail14
PDU TypeSwitched
TAA CompliantYes
Environmental CertificationRoHS
Environmentally FriendlyYes
Product TypePDU

Recently Viewed