Tripp Lite PDU Switched ATS 120V 20A 5-15/20R 16 Outlet L5-20P Horizontal TAA

Tripp Lite PDU Switched ATS 120V 20A 5-15/20R 16 Outlet L5-20P Horizontal TAA

SKU: 1010547797      MFR: Tripp Lite by Eaton

GTIN: 037332136411

Product Description

Tripp Lite PDU Switched ATS 120V 20A 5-15/20R 16 Outlet L5-20P Horizontal TAA - 16 x NEMA 5-15/20R - 2.4kVA - 1U Rack-mountable

Manufacturer : Tripp Lite by Eaton

Manufacturer Part No : PDUMH20ATNET

Features

  • 1.9kW 120V ATS / Switched PDU Single phase 20A 120V
  • Enables redundant A/B power option for single-corded network devices
  • Separate primary & secondary inputs connect to any two compatible power sources
  • 1U horizontal rackmount; 2 L5-20P / 5-20P inputs; 16 5-15/20R outlets
  • Individually switched outlets and Built-in LX Platform; Two digit visual current meter
  • Temperature humidity and contact closure monitoring options
  • TAA Compliant

Product Details

Product TypePDU
Receptacle TypeNEMA 5-15/20R
Environmentally FriendlyYes
Environmental CertificationRoHS
Number of Cord/Cable2
TAA CompliantYes
PDU TypeSwitched
Power Rating (VA)2400 VA
Product ColorBlack
Receptacle Detail16 x NEMA 5-15/20R
Plug/Connector Detail2 x NEMA L5-20P
Country of OriginTaiwan
Cord Length12
Height1.8"
Width1.8"
Depth14.5"
Certifications & Standards
  • 60950
  • Class A
  • TAA Compliant
Rack Height1U
Brand NameTripp Lite
Plug/Connector TypeNEMA L5-20P
Management
  • Integrated Automatic Transfer Switch (ATS) allows PDU to operate from secondary input source when primary input fails
  • Sequential outlet power-on prevents inrush-related equipment interaction on startup
  • Programmable or real-time monitoring and outlet power control via secure web/network interface
ManufacturerTripp Lite by Eaton
Product ModelPDUMH20ATNET
Product NamePDUMH20ATNET PDU Switched ATS 120V 20A 16 Outlet
Mount TypeRack-mountable
Input Voltage120 V AC
Manufacturer Part NumberPDUMH20ATNET
Manufacturer Website Addresshttp://www.tripplite.com
Marketing InformationTripp Lite Switched ATS / Auto Transfer Switch provides a redundant power option for single-corded network devices. Dual input cords support separate connection to PRIMARY and SECONDARY power sources. The ATS will normally maintain continuous output to all outlets as derived from the primary input cable. If the primary power source becomes unstable or fails altogether the ATS will switch over to the secondary power source until the primary input is restored and stable. The built-in Java-free HTML5-based LX Platform network interface enables full remote access for PDU status monitoring and email notifications via secure web browser SNMP telnet or SSH. It supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network. Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities. Protocols supported include IPv4 IPv6 HTTP HTTPS SMTP SNMPv1 SNMPv2 SNMPv3 telnet SSH FTP DHCP BOOTP and NTP. Switched PDU features include individually controllable output receptacles and built-in network interface. Super-fast switchover between primary and secondary power sources occurs within milliseconds. ATS functionality is supported by any two compatible AC power sources regardless of phase angle to support a variety of advanced redundant power networking applications. Enables fault tolerant hot-swappable UPS protection when used with a single UPS and fully redundant UPS protection when each cord is connected to a separate UPS system. In a two-UPS environment the primary input cable must be supported by a full time sine wave UPS with zero transfer time. Tripp Lite SmartOnline series is highly recommended for use as the primary UPS in a two-UPS application. ATS configurations utilizing separate mains circuits backup generators and even separate utility power grid feeds are fully supported. On-board ATS processor constantly evaluates power quality on both input sources to prevent transfer to the secondary source when unavailable or of lower quality than the primary source. Front input LED's display primary or secondary power availability.
Package Contents
  • PDUMH20ATNET PDU Switched ATS 120V 20A 16 Outlet
  • PDU with attached L5-20P input power cord
  • Detachable C19 to NEMA L5-20P 12 ft/3.6m power cord for optional secondary input
  • Two NEMA L5-20R to NEMA 5-20P plug adapters
  • User manual with warranty information
Limited Warranty2 Year
Output Voltage120 V AC
Weight (Approximate)12.20 lb
View full details
Regular price $1,128.99 USD
Regular price Sale price $1,128.99
Sale Sold out

Dropship


Update

   

Shipping calculated at checkout.

Tripp Lite PDU Switched ATS 120V 20A 5-15/20R 16 Outlet L5-20P Horizontal TAA - 16 x NEMA 5-15/20R - 2.4kVA - 1U Rack-mountable

Manufacturer : Tripp Lite by Eaton

Manufacturer Part No : PDUMH20ATNET

Features

  • 1.9kW 120V ATS / Switched PDU Single phase 20A 120V
  • Enables redundant A/B power option for single-corded network devices
  • Separate primary & secondary inputs connect to any two compatible power sources
  • 1U horizontal rackmount; 2 L5-20P / 5-20P inputs; 16 5-15/20R outlets
  • Individually switched outlets and Built-in LX Platform; Two digit visual current meter
  • Temperature humidity and contact closure monitoring options
  • TAA Compliant

Product Details

Product TypePDU
Receptacle TypeNEMA 5-15/20R
Environmentally FriendlyYes
Environmental CertificationRoHS
Number of Cord/Cable2
TAA CompliantYes
PDU TypeSwitched
Power Rating (VA)2400 VA
Product ColorBlack
Receptacle Detail16 x NEMA 5-15/20R
Plug/Connector Detail2 x NEMA L5-20P
Country of OriginTaiwan
Cord Length12
Height1.8"
Width1.8"
Depth14.5"
Certifications & Standards
  • 60950
  • Class A
  • TAA Compliant
Rack Height1U
Brand NameTripp Lite
Plug/Connector TypeNEMA L5-20P
Management
  • Integrated Automatic Transfer Switch (ATS) allows PDU to operate from secondary input source when primary input fails
  • Sequential outlet power-on prevents inrush-related equipment interaction on startup
  • Programmable or real-time monitoring and outlet power control via secure web/network interface
ManufacturerTripp Lite by Eaton
Product ModelPDUMH20ATNET
Product NamePDUMH20ATNET PDU Switched ATS 120V 20A 16 Outlet
Mount TypeRack-mountable
Input Voltage120 V AC
Manufacturer Part NumberPDUMH20ATNET
Manufacturer Website Addresshttp://www.tripplite.com
Marketing InformationTripp Lite Switched ATS / Auto Transfer Switch provides a redundant power option for single-corded network devices. Dual input cords support separate connection to PRIMARY and SECONDARY power sources. The ATS will normally maintain continuous output to all outlets as derived from the primary input cable. If the primary power source becomes unstable or fails altogether the ATS will switch over to the secondary power source until the primary input is restored and stable. The built-in Java-free HTML5-based LX Platform network interface enables full remote access for PDU status monitoring and email notifications via secure web browser SNMP telnet or SSH. It supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network. Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities. Protocols supported include IPv4 IPv6 HTTP HTTPS SMTP SNMPv1 SNMPv2 SNMPv3 telnet SSH FTP DHCP BOOTP and NTP. Switched PDU features include individually controllable output receptacles and built-in network interface. Super-fast switchover between primary and secondary power sources occurs within milliseconds. ATS functionality is supported by any two compatible AC power sources regardless of phase angle to support a variety of advanced redundant power networking applications. Enables fault tolerant hot-swappable UPS protection when used with a single UPS and fully redundant UPS protection when each cord is connected to a separate UPS system. In a two-UPS environment the primary input cable must be supported by a full time sine wave UPS with zero transfer time. Tripp Lite SmartOnline series is highly recommended for use as the primary UPS in a two-UPS application. ATS configurations utilizing separate mains circuits backup generators and even separate utility power grid feeds are fully supported. On-board ATS processor constantly evaluates power quality on both input sources to prevent transfer to the secondary source when unavailable or of lower quality than the primary source. Front input LED's display primary or secondary power availability.
Package Contents
  • PDUMH20ATNET PDU Switched ATS 120V 20A 16 Outlet
  • PDU with attached L5-20P input power cord
  • Detachable C19 to NEMA L5-20P 12 ft/3.6m power cord for optional secondary input
  • Two NEMA L5-20R to NEMA 5-20P plug adapters
  • User manual with warranty information
Limited Warranty2 Year
Output Voltage120 V AC
Weight (Approximate)12.20 lb

Recently Viewed