Skip to product information
1 of 1

Tripp Lite SmartOnline 208/120V UPS With Step-Down Transformer On-Line Double-Conversion 3000VA 2700W 4U Network Card Option

Tripp Lite SmartOnline 208/120V UPS With Step-Down Transformer On-Line Double-Conversion 3000VA 2700W 4U Network Card Option

SKU: 1061495673      MFR: Tripp Lite by Eaton

GTIN: 37332241719

Product Description

Tripp Lite SmartOnline 208/120V UPS With Step-Down Transformer On-Line Double-Conversion 3000VA 2700W 4U Network Card Option - 4U Rack/Tower - 3 Hour Recharge - 5 Minute Stand-by - 230 V AC Input - 120 V AC 208 V AC Output - 12 x NEMA 5-15/20R 6 x NEMA 6-15/20R 2 x NEMA L6-20R

Manufacturer : Tripp Lite by Eaton

Manufacturer Part No : SU3000LCD2UHVTF

Features

  • Offers protected 208V and 120V network-grade output power for critical IT applications
  • Zero transfer time between on-line and battery modes for uninterrupted operation
  • UPS + step-down transformer offer power protection of both 208V and 120V network devices
  • Optional external battery packs provide additional runtime for extended-run applications
  • Optional WEBCARDLX network interface required to use Auto Probe feature
  • 2-year limited warranty
  • $250000 Ultimate Lifetime Insurance

Product Details

Product TypeDouble Conversion Online UPS
PhaseSingle Phase
Receptacle TypeNEMA 5-15/20R
Environmentally FriendlyYes
Maximum Operating Temperature104°F (40°C)
Serial PortYes
Backup/Run Time (Half Load)13.50 Minute
Backup/Run Time (Full Load)5 Minute
EMI/RFI Noise FilterYes
Replaceable BatteryYes
DC System Voltage72 V DC
Energy SavingHigh Efficiency Economy Mode Operation; Individually Controllable Load Banks
EPO PortYes
USB (HID Compliant) PortYes
Maximum Operating Elevation9842.52 ft
Storage Temperature5°F (-15°C) - 122°F (50°C)
Transfer Time0 ns
Typical Battery Recharge Time3 Hour
Receptacle Detail12 x NEMA 5-15/20R
Country of OriginChina
Height7"
Width17.3"
Depth24.3"
Output Frequency60 Hz
AlarmPower Failure
Rack Height4U
Brand NameTripp Lite
Plug/Connector TypeNEMA L6-20P
Form FactorRack/Tower
Status Indicators

4 Front Panel LEDs:

  • AC Input (Green)
  • AC Output (Green)
  • Battery (Yellow)
  • Fault (Red)
Load Capacity3000 VA/2700 W
ManufacturerTripp Lite by Eaton
Product ModelSU3000LCD2UHVTF
Product NameSmartOnline SU3000LCD2UHVTF 3KVA Rack/Tower UPS
Network ManagementSNMP/DB9/USB
Product LineSmartOnline
Surge Energy Rating570 J
Thermal Dissipation273.44 W
Waveform TypePure Sine Wave
Application/UsageMission Critical Equipment
Hot SwappableYes
Input Voltage230 V AC
Manufacturer Part NumberSU3000LCD2UHVTF
Manufacturer Website Addresshttps://tripplite.eaton.com/
Marketing Information

2U Double-Conversion UPS Protects Equipment against Damage Downtime and Data Loss

This 208V and 120V 60 Hz UPS system maintains perfect output by converting AC input to DC then reconverting UPS output to fully regulated sine wave AC with +/-2% voltage regulation in both on-line and battery modes. Featuring a 2.7kW capacity high 0.9 power factor 570 joules of surge suppression true on-line operation with pure sine wave output and zero transfer time in on-line double-conversion mode the SmartOnline® SU3000LCD2UHVTF double-conversion UPS provides the highest level of AC power protection and battery backup for critical network closet computer room and data center equipment. With the included 2U step-down transformer this 3kVA UPS system can support both low- and high-voltage equipment.

Set Power Strategies to Reflect Your Protection Priorities

Pick your power strategy from precise power for sensitive systems to the highest possible electrical efficiency while ensuring 100% uptime. Choose from four selectable strategies: Max Efficiency Max Quality Frequency Regulation and Auto Adaptive which automatically offers increased efficiency when utility power conditions are good and enhanced power quality when power conditions are poor.

Individually Controllable Load Banks Let You Access and Control Outlets Remotely

The UPS and transformer combined feature 20 outlets in total-12 unswitched NEMA 5-15/20R on the transformer six NEMA 6-15/20R on the UPS and one unswitched NEMA L6-20R on each. Four NEMA 6-15/20R outlets are split into two switchable load banks allowing you to reboot select components or shed loads remotely.

Reliable Expandable Battery Backup Keeps You Operational Through Power Outages

The field-replaceable hot-swappable internal battery provides 13.5 minutes of support at half load (1350W) and five minutes at full load (2700W) keeping protected equipment operational through power failures. For mission-critical applications demanding scalable extended runtime the UPS supports "smart" external battery packs such as Tripp Lite's BP72V18-2US (sold separately). Both the internal batteries and sensor-enabled external battery packs are automatically sensed and configured during installation and replacement to offer accurate remaining runtime during outages and battery-age notifications. The intelligent battery management system with temperature-compensated charging extends battery life.

Automatic Bypass Maintains Utility Output During Fault Conditions

Auto-bypass mode keeps connected equipment powered and operational even during UPS fault conditions.

Automatically Turns Back On When Power Is Restored

Battery-independent restart ensures automatic UPS power-up without user interaction after lengthy power outages even when batteries are expired and require replacement.

Intuitive Front-Panel Interface for Convenient UPS Operation and Monitoring

The front-panel LCD screen reports UPS operating mode detailed UPS status and site-power information as well as a variety of advanced UPS setup and configuration options. LEDs indicate AC input/output battery and fault status.

Advanced Communications Ports Allow for Automatic Saves and Shutdowns

RS-232 and HID-compliant USB ports connect to a computer running Tripp Lite's free downloadable PowerAlert® software to enable safe unattended file saves and system shutdown in case of a prolonged power failure. An EPO port connects the UPS to a contact closure switch to enable emergency inverter shutdown. Cables are included.

Package Contents
  • SmartOnline SU3000LCD2UHVTF 3KVA Rack/Tower UPS
  • SU5000XFMRT2U20 2U 208V to 120V Step-Down Isolation Transformer
  • USB Cable
  • DB9 Cable
  • EPO Cable
  • Rack-mounting Hardware
  • Owner's Manual
Limited Warranty2 Year
Output Voltage120 V AC
Weight (Approximate)133.82 lb
Product FamilySmartOnline
Load Capacity (VA)3000 VA
Load Capacity (W)2700 W
View full details
Regular price $5,565.99 USD
Regular price Sale price $5,565.99
Sale Sold out

Dropship


Update

   

Shipping calculated at checkout.

Tripp Lite SmartOnline 208/120V UPS With Step-Down Transformer On-Line Double-Conversion 3000VA 2700W 4U Network Card Option - 4U Rack/Tower - 3 Hour Recharge - 5 Minute Stand-by - 230 V AC Input - 120 V AC 208 V AC Output - 12 x NEMA 5-15/20R 6 x NEMA 6-15/20R 2 x NEMA L6-20R

Manufacturer : Tripp Lite by Eaton

Manufacturer Part No : SU3000LCD2UHVTF

Features

  • Offers protected 208V and 120V network-grade output power for critical IT applications
  • Zero transfer time between on-line and battery modes for uninterrupted operation
  • UPS + step-down transformer offer power protection of both 208V and 120V network devices
  • Optional external battery packs provide additional runtime for extended-run applications
  • Optional WEBCARDLX network interface required to use Auto Probe feature
  • 2-year limited warranty
  • $250000 Ultimate Lifetime Insurance

Product Details

Product TypeDouble Conversion Online UPS
PhaseSingle Phase
Receptacle TypeNEMA 5-15/20R
Environmentally FriendlyYes
Maximum Operating Temperature104°F (40°C)
Serial PortYes
Backup/Run Time (Half Load)13.50 Minute
Backup/Run Time (Full Load)5 Minute
EMI/RFI Noise FilterYes
Replaceable BatteryYes
DC System Voltage72 V DC
Energy SavingHigh Efficiency Economy Mode Operation; Individually Controllable Load Banks
EPO PortYes
USB (HID Compliant) PortYes
Maximum Operating Elevation9842.52 ft
Storage Temperature5°F (-15°C) - 122°F (50°C)
Transfer Time0 ns
Typical Battery Recharge Time3 Hour
Receptacle Detail12 x NEMA 5-15/20R
Country of OriginChina
Height7"
Width17.3"
Depth24.3"
Output Frequency60 Hz
AlarmPower Failure
Rack Height4U
Brand NameTripp Lite
Plug/Connector TypeNEMA L6-20P
Form FactorRack/Tower
Status Indicators

4 Front Panel LEDs:

  • AC Input (Green)
  • AC Output (Green)
  • Battery (Yellow)
  • Fault (Red)
Load Capacity3000 VA/2700 W
ManufacturerTripp Lite by Eaton
Product ModelSU3000LCD2UHVTF
Product NameSmartOnline SU3000LCD2UHVTF 3KVA Rack/Tower UPS
Network ManagementSNMP/DB9/USB
Product LineSmartOnline
Surge Energy Rating570 J
Thermal Dissipation273.44 W
Waveform TypePure Sine Wave
Application/UsageMission Critical Equipment
Hot SwappableYes
Input Voltage230 V AC
Manufacturer Part NumberSU3000LCD2UHVTF
Manufacturer Website Addresshttps://tripplite.eaton.com/
Marketing Information

2U Double-Conversion UPS Protects Equipment against Damage Downtime and Data Loss

This 208V and 120V 60 Hz UPS system maintains perfect output by converting AC input to DC then reconverting UPS output to fully regulated sine wave AC with +/-2% voltage regulation in both on-line and battery modes. Featuring a 2.7kW capacity high 0.9 power factor 570 joules of surge suppression true on-line operation with pure sine wave output and zero transfer time in on-line double-conversion mode the SmartOnline® SU3000LCD2UHVTF double-conversion UPS provides the highest level of AC power protection and battery backup for critical network closet computer room and data center equipment. With the included 2U step-down transformer this 3kVA UPS system can support both low- and high-voltage equipment.

Set Power Strategies to Reflect Your Protection Priorities

Pick your power strategy from precise power for sensitive systems to the highest possible electrical efficiency while ensuring 100% uptime. Choose from four selectable strategies: Max Efficiency Max Quality Frequency Regulation and Auto Adaptive which automatically offers increased efficiency when utility power conditions are good and enhanced power quality when power conditions are poor.

Individually Controllable Load Banks Let You Access and Control Outlets Remotely

The UPS and transformer combined feature 20 outlets in total-12 unswitched NEMA 5-15/20R on the transformer six NEMA 6-15/20R on the UPS and one unswitched NEMA L6-20R on each. Four NEMA 6-15/20R outlets are split into two switchable load banks allowing you to reboot select components or shed loads remotely.

Reliable Expandable Battery Backup Keeps You Operational Through Power Outages

The field-replaceable hot-swappable internal battery provides 13.5 minutes of support at half load (1350W) and five minutes at full load (2700W) keeping protected equipment operational through power failures. For mission-critical applications demanding scalable extended runtime the UPS supports "smart" external battery packs such as Tripp Lite's BP72V18-2US (sold separately). Both the internal batteries and sensor-enabled external battery packs are automatically sensed and configured during installation and replacement to offer accurate remaining runtime during outages and battery-age notifications. The intelligent battery management system with temperature-compensated charging extends battery life.

Automatic Bypass Maintains Utility Output During Fault Conditions

Auto-bypass mode keeps connected equipment powered and operational even during UPS fault conditions.

Automatically Turns Back On When Power Is Restored

Battery-independent restart ensures automatic UPS power-up without user interaction after lengthy power outages even when batteries are expired and require replacement.

Intuitive Front-Panel Interface for Convenient UPS Operation and Monitoring

The front-panel LCD screen reports UPS operating mode detailed UPS status and site-power information as well as a variety of advanced UPS setup and configuration options. LEDs indicate AC input/output battery and fault status.

Advanced Communications Ports Allow for Automatic Saves and Shutdowns

RS-232 and HID-compliant USB ports connect to a computer running Tripp Lite's free downloadable PowerAlert® software to enable safe unattended file saves and system shutdown in case of a prolonged power failure. An EPO port connects the UPS to a contact closure switch to enable emergency inverter shutdown. Cables are included.

Package Contents
  • SmartOnline SU3000LCD2UHVTF 3KVA Rack/Tower UPS
  • SU5000XFMRT2U20 2U 208V to 120V Step-Down Isolation Transformer
  • USB Cable
  • DB9 Cable
  • EPO Cable
  • Rack-mounting Hardware
  • Owner's Manual
Limited Warranty2 Year
Output Voltage120 V AC
Weight (Approximate)133.82 lb
Product FamilySmartOnline
Load Capacity (VA)3000 VA
Load Capacity (W)2700 W

Recently Viewed