Tripp Lite UPS Maintenance Bypass Panel for SVT10KX - 3 Breakers - 480 V AC

Manufacturer : Tripp Lite by Eaton

Manufacturer Part No : SU10KMBPKX

Features

  • Isolates UPS from connected loads for maintenance without losing network availability
  • Maintenance bypass panel mounts to wall next to UPS for convenient access
  • 40A 10 kAIC unit has 3 built-in circuit breakers connected to heavy-duty buswork
  • Secure Kirk-key interlock system prevents unauthorized access to power
  • Compatible with Tripp Lite's SVT10KX 3-phase UPS system

Product Details

Product NameUPS Maintenance Bypass Panel for SVT10KX - 3 Breakers
Input Voltage480 V AC
Manufacturer Part NumberSU10KMBPKX
Manufacturer Website Addresshttps://tripplite.eaton.com/
Marketing InformationUPS Maintenance Bypass Panel Keeps Equipment Powered During UPS MaintenanceThis wallmount three-breaker maintenance bypass panel is compatible with Tripp Lite's SVT10KX 3-phase UPS system. It allows you to reroute power around the UPS providing an alternate path for electricity that keeps the connected load operational while the UPS is offline for maintenance or repairs.

Features 3 Built-In Circuit Breakers to Isolate LoadsThree circuit breakers - an AC input breaker a maintenance bypass breaker and a maintenance isolation breaker - are connected to heavy-duty buswork and isolate the UPS system from its connected load with no loss of network availability. This allows the load to remain continuously powered without costly downtime. A Kirk-key interlock system enhances safety and security. Removable handles allow the panel's trim cover to be removed for internal access. The 40A unit has a kAIC rating of 10K.

Switching Between Normal and Bypass Modes Is EasyWhen a UPS needs maintenance this UPS bypass panel keeps power supplied to components via its mechanical interlock system by switching power to the external bypass breaker. Simply unscrew the interlock switch rotate the switch from the UPS AC input breaker (SW1) to the bypass breaker (SW2) then turn on the bypass breaker and turn off the UPS and isolation breaker (SW3) to perform UPS maintenance without service interruption.

Convenient Wall-Mount InstallationMade of galvanized steel the service bypass panel has rear mounting holes for installation on a smooth solid wall (mounting hardware not included).
Package Contents
  • UPS Maintenance Bypass Panel for SVT10KX - 3 Breakers
  • Installation and Operation Manual
Limited Warranty1 Year
Weight (Approximate)55 lb
Product TypeBypass Panel
Brand NameTripp Lite
Country of OriginUnited States
Height24"
Width22"
Depth10"
CompatibilityTripp Lite's SVT10KX 3-phase UPS system
Form FactorWall-mountable
ManufacturerTripp Lite by Eaton
Product ModelSU10KMBPKX
View full details
Regular price $5,238.99 USD
Regular price Sale price $5,238.99
Sale Sold out

Out Of Stock


Update

   

Shipping calculated at checkout.

Tripp Lite UPS Maintenance Bypass Panel for SVT10KX - 3 Breakers - 480 V AC

Manufacturer : Tripp Lite by Eaton

Manufacturer Part No : SU10KMBPKX

Features

  • Isolates UPS from connected loads for maintenance without losing network availability
  • Maintenance bypass panel mounts to wall next to UPS for convenient access
  • 40A 10 kAIC unit has 3 built-in circuit breakers connected to heavy-duty buswork
  • Secure Kirk-key interlock system prevents unauthorized access to power
  • Compatible with Tripp Lite's SVT10KX 3-phase UPS system

Product Details

Product NameUPS Maintenance Bypass Panel for SVT10KX - 3 Breakers
Input Voltage480 V AC
Manufacturer Part NumberSU10KMBPKX
Manufacturer Website Addresshttps://tripplite.eaton.com/
Marketing InformationUPS Maintenance Bypass Panel Keeps Equipment Powered During UPS MaintenanceThis wallmount three-breaker maintenance bypass panel is compatible with Tripp Lite's SVT10KX 3-phase UPS system. It allows you to reroute power around the UPS providing an alternate path for electricity that keeps the connected load operational while the UPS is offline for maintenance or repairs.

Features 3 Built-In Circuit Breakers to Isolate LoadsThree circuit breakers - an AC input breaker a maintenance bypass breaker and a maintenance isolation breaker - are connected to heavy-duty buswork and isolate the UPS system from its connected load with no loss of network availability. This allows the load to remain continuously powered without costly downtime. A Kirk-key interlock system enhances safety and security. Removable handles allow the panel's trim cover to be removed for internal access. The 40A unit has a kAIC rating of 10K.

Switching Between Normal and Bypass Modes Is EasyWhen a UPS needs maintenance this UPS bypass panel keeps power supplied to components via its mechanical interlock system by switching power to the external bypass breaker. Simply unscrew the interlock switch rotate the switch from the UPS AC input breaker (SW1) to the bypass breaker (SW2) then turn on the bypass breaker and turn off the UPS and isolation breaker (SW3) to perform UPS maintenance without service interruption.

Convenient Wall-Mount InstallationMade of galvanized steel the service bypass panel has rear mounting holes for installation on a smooth solid wall (mounting hardware not included).
Package Contents
  • UPS Maintenance Bypass Panel for SVT10KX - 3 Breakers
  • Installation and Operation Manual
Limited Warranty1 Year
Weight (Approximate)55 lb
Product TypeBypass Panel
Brand NameTripp Lite
Country of OriginUnited States
Height24"
Width22"
Depth10"
CompatibilityTripp Lite's SVT10KX 3-phase UPS system
Form FactorWall-mountable
ManufacturerTripp Lite by Eaton